Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
34
matching recommendationsNAICS | 311941 | Mayonnaise, Dressing, and Other Prepared Sauce Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0450 # 03 Y:2012 | 03 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,833 | $1,900 | Not Implemented |
SD0450 # 02 Y:2012 | 02 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,795 | $200 | Not Implemented |
SD0450 # 01 Y:2012 | 01 | 2012 | USE MINIMUM STEAM OPERATING PRESSURE | $8,111 | $200 | Not Implemented |
SD0450 # 05 Y:2012 | 05 | 2012 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $8,500 | $25,000 | Not Implemented |
SD0450 # 04 Y:2012 | 04 | 2012 | USE PHOTOCELL CONTROLS | $1,297 | $3,550 | Not Implemented |
SD0436 # 04 Y:2011 | 04 | 2011 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $1,787 | $1,535 | Implemented |
SD0436 # 10 Y:2011 | 10 | 2011 | UPGRADE OBSOLETE EQUIPMENT | $20,930 | $61,200 | Not Implemented |
SD0436 # 09 Y:2011 | 09 | 2011 | INSTALL SKYLIGHTS | $6,479 | $14,200 | Not Implemented |
SD0436 # 08 Y:2011 | 08 | 2011 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $283,465 | $607,200 | Not Implemented |
SD0436 # 07 Y:2011 | 07 | 2011 | INCREASE AMOUNT OF CONDENSATE RETURNED | $12,828 | $20,000 | Implemented |
SD0436 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $35,598 | $52,274 | Implemented |
SD0436 # 05 Y:2011 | 05 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $26,197 | $22,700 | Not Implemented |
SD0436 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $7,888 | $6,050 | Implemented |
SD0436 # 02 Y:2011 | 02 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,180 | $2,000 | Implemented |
SD0436 # 01 Y:2011 | 01 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,198 | $2,100 | Implemented |
SD0502 # 01 Y:2010 | 01 | 2010 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $17,800 | $10,000 | Implemented |
SD0502 # 02 Y:2010 | 02 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $12,170 | $1,000 | Implemented |
SD0502 # 03 Y:2010 | 03 | 2010 | INCREASE AMOUNT OF CONDENSATE RETURNED | $15,940 | $2,263 | Not Implemented |
SD0502 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $49,905 | $161,162 | Implemented |
SD0419 # 02 Y:2009 | 02 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $12,170 | $1,000 | Implemented |
SD0419 # 07 Y:2009 | 07 | 2009 | INSTALL TIMERS AND/OR THERMOSTATS | $14,906 | $500 | Not Implemented |
SD0419 # 06 Y:2009 | 06 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $39,102 | $50,136 | Not Implemented |
SD0419 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $49,905 | $161,162 | Implemented |
SD0419 # 04 Y:2009 | 04 | 2009 | INCREASE AMOUNT OF CONDENSATE RETURNED | $15,940 | $2,263 | Implemented |
SD0419 # 03 Y:2009 | 03 | 2009 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $7,840 | $10,000 | Not Implemented |