Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
452
matching recommendationsNAICS | 3121 | Beverage Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0427 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $486 | $2,200 | Not Implemented |
SD0427 # 06 Y:2010 | 06 | 2010 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $540,797 | $1,949,400 | Not Implemented |
SF0383 # 01 Y:2010 | 01 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $229 | $40 | Not Implemented |
SF0383 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $245 | $618 | Not Implemented |
SF0383 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,563 | $42,318 | Not Implemented |
SF0383 # 04 Y:2010 | 04 | 2010 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,697 | $28,699 | Not Implemented |
SF0383 # 05 Y:2010 | 05 | 2010 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $4,340 | $20,638 | Not Implemented |
SF0383 # 06 Y:2010 | 06 | 2010 | INSULATE BARE EQUIPMENT | $222 | $1,278 | Not Implemented |
SF0383 # 07 Y:2010 | 07 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,819 | $14,000 | Not Implemented |
SF0383 # 08 Y:2010 | 08 | 2010 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,999 | $26,118 | Not Implemented |
SF0369 # 01 Y:2009 | 01 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $739 | $70 | Implemented |
SF0369 # 02 Y:2009 | 02 | 2009 | REPAIR AND ELIMINATE STEAM LEAKS | $565 | $60 | Implemented |
SF0369 # 03 Y:2009 | 03 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $15,017 | $14,000 | Implemented |
SF0369 # 04 Y:2009 | 04 | 2009 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $34,213 | $37,500 | Implemented |
SF0369 # 05 Y:2009 | 05 | 2009 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $16,866 | $26,548 | Not Implemented |
SF0369 # 06 Y:2009 | 06 | 2009 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $1,751 | $3,312 | Not Implemented |
SF0369 # 07 Y:2009 | 07 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $328 | $1,039 | Not Implemented |
SF0369 # 08 Y:2009 | 08 | 2009 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $7,253 | $41,149 | Not Implemented |
SF0363 # 01 Y:2008 | 01 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $2,927 | $0 | Implemented |
SF0363 # 02 Y:2008 | 02 | 2008 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $968 | $1,145 | Implemented |
SF0363 # 03 Y:2008 | 03 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,754 | $3,506 | Implemented |
SF0363 # 04 Y:2008 | 04 | 2008 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $6,525 | $14,831 | Not Implemented |
SF0363 # 05 Y:2008 | 05 | 2008 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $9,481 | $69,656 | Not Implemented |
SF0356 # 01 Y:2008 | 01 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,321 | $150 | Not Implemented |
SF0356 # 02 Y:2008 | 02 | 2008 | MAKE ICE DURING OFF PEAK HOURS FOR COOLING | $41,503 | $0 | Not Implemented |