Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
57
matching recommendationsNAICS | 3121 | Beverage Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0370 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $17,172 | $8,188 | Implemented |
UM0370 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $76,860 | $90,000 | Implemented |
UM0352 # 03 Y:2009 | 03 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,300 | $1,700 | Implemented |
UM0352 # 01 Y:2009 | 01 | 2009 | INSULATE FEEDWATER TANK | $8,739 | $3,454 | Implemented |
UM0352 # 02 Y:2009 | 02 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,001 | $11,363 | Not Implemented |
UM0352 # 05 Y:2009 | 05 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,200 | $0 | Implemented |
UM0352 # 06 Y:2009 | 06 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,800 | $1,900 | Not Implemented |
UM0352 # 07 Y:2009 | 07 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,454 | $0 | Implemented |
UM0352 # 08 Y:2009 | 08 | 2009 | INSTALL OCCUPANCY SENSORS | $504 | $920 | Implemented |
UM0352 # 09 Y:2009 | 09 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,944 | $1,200 | Implemented |
UM0352 # 04 Y:2009 | 04 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,569 | $1,060 | Not Implemented |
UM0321 # 02 Y:2007 | 02 | 2007 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $11,520 | $21,700 | Not Implemented |
UM0321 # 01 Y:2007 | 01 | 2007 | USE HEAT PUMP FOR SPACE CONDITIONING | $33,455 | $21,730 | Not Implemented |
UM0321 # 03 Y:2007 | 03 | 2007 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $9,993 | $1,000 | Implemented |
UM0321 # 04 Y:2007 | 04 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,307 | $1,000 | Implemented |
UM0321 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,338 | $0 | Implemented |
UM0321 # 06 Y:2007 | 06 | 2007 | TREAT AND REUSE RINSE WATERS | $3,084 | $8,021 | Not Implemented |
UM0321 # 07 Y:2007 | 07 | 2007 | INSTALL OCCUPANCY SENSORS | $1,558 | $5,130 | Implemented |
UM0319 # 09 Y:2007 | 09 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,223 | $86,000 | Implemented |
UM0319 # 07 Y:2007 | 07 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,128 | $2,200 | Implemented |
UM0319 # 06 Y:2007 | 06 | 2007 | MINIMIZE WATER USAGE | $15,684 | $0 | Not Implemented |
UM0319 # 05 Y:2007 | 05 | 2007 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $20,590 | $0 | Not Implemented |
UM0319 # 04 Y:2007 | 04 | 2007 | REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING | $33,973 | $300,000 | Implemented |
UM0319 # 03 Y:2007 | 03 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $28,235 | $20,000 | Implemented |
UM0319 # 02 Y:2007 | 02 | 2007 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $31,763 | $0 | Not Implemented |