Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,033
matching recommendationsNAICS | 3121 | Beverage Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0363 # 01 Y:2008 | 01 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $2,927 | $0 | Implemented |
SF0363 # 02 Y:2008 | 02 | 2008 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $968 | $1,145 | Implemented |
SF0363 # 03 Y:2008 | 03 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,754 | $3,506 | Implemented |
SF0363 # 04 Y:2008 | 04 | 2008 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $6,525 | $14,831 | Not Implemented |
SF0363 # 05 Y:2008 | 05 | 2008 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $9,481 | $69,656 | Not Implemented |
DL0015 # 01 Y:2008 | 01 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $20,000 | $400 | Not Implemented |
DL0015 # 02 Y:2008 | 02 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,400 | $3,500 | Implemented |
DL0015 # 03 Y:2008 | 03 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $19,500 | $20,000 | Implemented |
DL0015 # 04 Y:2008 | 04 | 2008 | ADD AREA LIGHTING SWITCHES | $370 | $1,500 | Implemented |
DL0015 # 05 Y:2008 | 05 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,911 | $2,500 | Implemented |
DL0015 # 06 Y:2008 | 06 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,000 | $16,000 | Not Implemented |
DL0015 # 07 Y:2008 | 07 | 2008 | REPLACE BOILER | $13,000 | $20,000 | Not Implemented |
DL0015 # 08 Y:2008 | 08 | 2008 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $15,400 | $27,000 | Not Implemented |
DL0015 # 09 Y:2008 | 09 | 2008 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $2,970 | $10,000 | Not Implemented |
DL0015 # 10 Y:2008 | 10 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,249 | $18,000 | Implemented |
UA0021 # 01 Y:2008 | 01 | 2008 | UPGRADE CONTROLS ON COMPRESSORS | $12,169 | $6,000 | Not Implemented |
UA0021 # 02 Y:2008 | 02 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,811 | $2,000 | Implemented |
UA0021 # 03 Y:2008 | 03 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,288 | $3,000 | Implemented |
UA0021 # 04 Y:2008 | 04 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,835 | $0 | Implemented |
UA0021 # 05 Y:2008 | 05 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,804 | $8,000 | Not Implemented |
UA0021 # 06 Y:2008 | 06 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,292 | $2,550 | Not Implemented |
UA0021 # 07 Y:2008 | 07 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $6,002 | $986 | Implemented |
UA0021 # 08 Y:2008 | 08 | 2008 | INSTALL OCCUPANCY SENSORS | $278 | $271 | Not Implemented |
UA0021 # 09 Y:2008 | 09 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,436 | $49,534 | Not Implemented |
UA0021 # 10 Y:2008 | 10 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,186 | $1,050 | Not Implemented |