Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

256

matching recommendations
Reset
NAICS 313310 Textile and Fabric Finishing Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MZ0012 # 04 Y:2007 04 2007 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $574 $900 Implemented
MZ0012 # 05 Y:2007 05 2007 INSTALL OCCUPANCY SENSORS $215 $180 Implemented
TT0003 # 01 Y:2007 01 2007 OPTIMIZE PLANT POWER FACTOR $9,260 $30,000 Not Implemented
TT0003 # 02 Y:2007 02 2007 REPLACE BOILER $1,896 $15,000 Not Implemented
TT0003 # 03 Y:2007 03 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $38,338 $42,670 Not Implemented
TT0003 # 04 Y:2007 04 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,406 $5,360 Not Implemented
TT0003 # 05 Y:2007 05 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $250 $450 Not Implemented
TT0003 # 06 Y:2007 06 2007 RECOVER WASTE HEAT FROM EQUIPMENT $3,379 $1,500 Not Implemented
TT0003 # 07 Y:2007 07 2007 INSULATE BARE EQUIPMENT $5,016 $1,000 Not Implemented
TT0003 # 08 Y:2007 08 2007 USE COMPRESSOR AIR FILTERS $1,524 $400 Not Implemented
TT0003 # 09 Y:2007 09 2007 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,592 $2,250 Not Implemented
TT0003 # 10 Y:2007 10 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,574 $1,100 Not Implemented
TT0003 # 11 Y:2007 11 2007 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $4,824 $0 Not Implemented
NC0357 # 01 Y:2007 01 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $30,234 $78,000 Not Implemented
NC0357 # 02 Y:2007 02 2007 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $16,558 $5,600 Not Implemented
NC0357 # 03 Y:2007 03 2007 DEVELOP A REPAIR/REPLACE POLICY $699 $375 Not Implemented
NC0357 # 04 Y:2007 04 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,527 $4,761 Not Implemented
NC0357 # 05 Y:2007 05 2007 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $277 $100 Implemented
LM0121 # 01 Y:2006 01 2006 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY $183,000 $2,160 Not Implemented
LM0121 # 02 Y:2006 02 2006 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY $91,500 $200 Not Implemented
LM0121 # 03 Y:2006 03 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,390 $10,233 Implemented
LM0121 # 04 Y:2006 04 2006 INSULATE BARE EQUIPMENT $3,734 $3,100 Implemented
MS0295 # 01 Y:2006 01 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $24,158 $36,274 Implemented
MS0295 # 02 Y:2006 02 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $21,061 $87,943 Implemented
MS0295 # 03 Y:2006 03 2006 REPAIR AND ELIMINATE STEAM LEAKS $6,813 $37 Implemented