Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
15
matching recommendationsNAICS | 31332 | Fabric Coating Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0199 # 01 Y:2017 | 01 | 2017 | CLEAN FOULING FROM WATER LINES REGULARLY | $91,197 | $8,500 | Not Implemented |
TT0199 # 02 Y:2017 | 02 | 2017 | REPAIR OR REPLACE STEAM TRAPS | $14,682 | $4,830 | Not Implemented |
TT0199 # 03 Y:2017 | 03 | 2017 | OPTIMIZE PLANT POWER FACTOR | $5,729 | $8,000 | Not Implemented |
TT0199 # 04 Y:2017 | 04 | 2017 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,003 | $25 | Not Implemented |
TT0199 # 05 Y:2017 | 05 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,715 | $11,600 | Not Implemented |
TT0078 # 01 Y:2011 | 01 | 2011 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $8,585 | $29,500 | Not Implemented |
TT0078 # 02 Y:2011 | 02 | 2011 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $10,364 | $5,531 | Not Implemented |
TT0078 # 03 Y:2011 | 03 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $7,023 | $1,480 | Implemented |
TT0078 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,720 | $800 | Implemented |
TT0078 # 05 Y:2011 | 05 | 2011 | USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER | $15,241 | $12,500 | Not Implemented |
TT0067 # 01 Y:2011 | 01 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $303,919 | $125,000 | Not Implemented |
TT0018 # 01 Y:2008 | 01 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $314,600 | $100,000 | Not Implemented |
TT0018 # 02 Y:2008 | 02 | 2008 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $33,000 | $1,000 | Implemented |
TT0018 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,809 | $22,423 | Implemented |
TT0018 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,637 | $5,950 | Implemented |