Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
539
matching recommendationsNAICS | 314 | Textile Product Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0784 # 09 Y:2009 | 09 | 2009 | INSTALL TIMERS AND/OR THERMOSTATS | $858 | $990 | Implemented |
WV0393 # 10 Y:2009 | 10 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $764 | $220 | Not Implemented |
WV0393 # 11 Y:2009 | 11 | 2009 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $554 | $56 | Implemented |
WV0393 # 12 Y:2009 | 12 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $419 | $20 | Implemented |
WV0393 # 13 Y:2009 | 13 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $370 | $0 | Implemented |
WV0393 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $69,642 | $143,500 | Implemented |
WV0393 # 02 Y:2009 | 02 | 2009 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $45,591 | $127,000 | Not Implemented |
WV0393 # 03 Y:2009 | 03 | 2009 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $8,129 | $2,000 | Implemented |
WV0393 # 04 Y:2009 | 04 | 2009 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $5,419 | $4,400 | Not Implemented |
WV0393 # 05 Y:2009 | 05 | 2009 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $4,441 | $7,800 | Not Implemented |
WV0393 # 06 Y:2009 | 06 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,691 | $2,450 | Not Implemented |
WV0393 # 07 Y:2009 | 07 | 2009 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $2,298 | $3,800 | Implemented |
WV0393 # 08 Y:2009 | 08 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,009 | $500 | Implemented |
WV0393 # 09 Y:2009 | 09 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,723 | $2,067 | Not Implemented |
MS0341 # 01 Y:2009 | 01 | 2009 | INSTALL DESICCANT HUMIDITY CONTROL SYSTEM | $42,353 | $102,915 | Not Implemented |
MS0341 # 02 Y:2009 | 02 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $13,482 | $217,200 | Not Implemented |
MS0341 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,112 | $38,096 | Implemented |
MS0341 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,747 | $15,590 | Implemented |
MS0341 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,400 | $196 | Implemented |
SU0278 # 01 Y:2009 | 01 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $25,359 | $0 | Implemented |
SU0278 # 02 Y:2009 | 02 | 2009 | USE SYNTHETIC LUBRICANT | $8,358 | $0 | Not Implemented |
SU0278 # 03 Y:2009 | 03 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,050 | $0 | Implemented |
SU0278 # 04 Y:2009 | 04 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,305 | $528 | Implemented |
SU0278 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,615 | $410 | Implemented |
SU0278 # 06 Y:2009 | 06 | 2009 | INSTALL OCCUPANCY SENSORS | $44,212 | $7,299 | Implemented |