Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
539
matching recommendationsNAICS | 314 | Textile Product Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0278 # 07 Y:2009 | 07 | 2009 | INSULATE BARE EQUIPMENT | $1,289 | $1,820 | Not Implemented |
SU0278 # 08 Y:2009 | 08 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,049 | $6,721 | Implemented |
SU0278 # 09 Y:2009 | 09 | 2009 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $112 | $271 | Not Implemented |
SU0278 # 10 Y:2009 | 10 | 2009 | OPTIMIZE PLANT POWER FACTOR | $7,344 | $28,458 | Implemented |
WV0387 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $43,474 | $56,368 | Implemented |
WV0387 # 02 Y:2009 | 02 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,123 | $12,560 | Not Implemented |
WV0387 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,978 | $0 | Implemented |
WV0387 # 04 Y:2009 | 04 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,801 | $1,480 | Not Implemented |
WV0387 # 05 Y:2009 | 05 | 2009 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,208 | $47 | Not Implemented |
WV0387 # 06 Y:2009 | 06 | 2009 | OPTIMIZE PLANT POWER FACTOR | $3,260 | $4,450 | Not Implemented |
WV0387 # 07 Y:2009 | 07 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,818 | $148 | Implemented |
WV0387 # 08 Y:2009 | 08 | 2009 | DEVELOP A REPAIR/REPLACE POLICY | $2,515 | $651 | Implemented |
WV0387 # 09 Y:2009 | 09 | 2009 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,292 | $3,840 | Not Implemented |
WV0387 # 10 Y:2009 | 10 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,892 | $0 | Implemented |
WV0387 # 11 Y:2009 | 11 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,753 | $460 | Not Implemented |
WV0387 # 12 Y:2009 | 12 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,520 | $28 | Implemented |
GT0846 # 01 Y:2008 | 01 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $61,777 | $40,000 | Implemented |
GT0846 # 02 Y:2008 | 02 | 2008 | USE MINIMUM STEAM OPERATING PRESSURE | $16,146 | $15,536 | Implemented |
GT0846 # 03 Y:2008 | 03 | 2008 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $830 | $1,094 | Not Implemented |
GT0846 # 04 Y:2008 | 04 | 2008 | USE STEAM CONDENSATE FOR HOT WATER SUPPLY (NON-POTABLE) | $17,989 | $26,900 | Not Implemented |
GT0846 # 05 Y:2008 | 05 | 2008 | HEAT WATER WITH EXHAUST HEAT | $551,313 | $130,000 | Not Implemented |
GT0846 # 06 Y:2008 | 06 | 2008 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $59,040 | $65,000 | Implemented |
GT0846 # 07 Y:2008 | 07 | 2008 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $155,720 | $30,000 | Implemented |
GT0846 # 08 Y:2008 | 08 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,504 | $70,103 | Implemented |
GT0846 # 09 Y:2008 | 09 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $18,206 | $35,000 | Not Implemented |