Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
140
matching recommendationsNAICS | 314 | Textile Product Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0170 # 04 Y:2016 | 04 | 2016 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,630 | $3,525 | Implemented |
TT0170 # 05 Y:2016 | 05 | 2016 | INSULATE BARE EQUIPMENT | $1,494 | $130 | Implemented |
TT0156 # 01 Y:2015 | 01 | 2015 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $31,925 | $52,507 | Not Implemented |
TT0156 # 02 Y:2015 | 02 | 2015 | REPAIR AND ELIMINATE STEAM LEAKS | $13,551 | $15,000 | Not Implemented |
TT0156 # 03 Y:2015 | 03 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,241 | $10,000 | Not Implemented |
TT0156 # 04 Y:2015 | 04 | 2015 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $3,000 | $5,000 | Not Implemented |
TT0156 # 05 Y:2015 | 05 | 2015 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,769 | $1,651 | Implemented |
TT0156 # 06 Y:2015 | 06 | 2015 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,454 | $13 | Implemented |
GT0883 # 01 Y:2011 | 01 | 2011 | INSULATE BARE EQUIPMENT | $1,910 | $242 | n/a |
GT0883 # 02 Y:2011 | 02 | 2011 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $4,435 | $800 | n/a |
GT0883 # 03 Y:2011 | 03 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,504 | $36,650 | n/a |
GT0883 # 04 Y:2011 | 04 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $34,385 | $107,085 | n/a |
GT0883 # 05 Y:2011 | 05 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,404 | $46,133 | n/a |
GT0883 # 06 Y:2011 | 06 | 2011 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $42,689 | $368,265 | n/a |
GT0883 # 07 Y:2011 | 07 | 2011 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $10,194 | $7,000 | n/a |
GT0876 # 01 Y:2010 | 01 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,786 | $1,500 | Implemented |
GT0876 # 02 Y:2010 | 02 | 2010 | INSTALL REDUNDANT EQUIPMENT TO AVOID LOSSES CAUSED BY EQUIPMENT FAILURE AND ROUTINE MAINTENANCE | $307 | $50 | Not Implemented |
GT0876 # 03 Y:2010 | 03 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,989 | $10,500 | Not Implemented |
GT0876 # 04 Y:2010 | 04 | 2010 | REPAIR AND ELIMINATE STEAM LEAKS | $1,027 | $300 | Implemented |
GT0876 # 05 Y:2010 | 05 | 2010 | USE OPTIMUM TEMPERATURE | $103,726 | $187,530 | Implemented |
GT0876 # 06 Y:2010 | 06 | 2010 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $10,041 | $20,000 | Not Implemented |
GT0846 # 01 Y:2008 | 01 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $61,777 | $40,000 | Implemented |
GT0846 # 02 Y:2008 | 02 | 2008 | USE MINIMUM STEAM OPERATING PRESSURE | $16,146 | $15,536 | Implemented |
GT0846 # 03 Y:2008 | 03 | 2008 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $830 | $1,094 | Not Implemented |
GT0846 # 04 Y:2008 | 04 | 2008 | USE STEAM CONDENSATE FOR HOT WATER SUPPLY (NON-POTABLE) | $17,989 | $26,900 | Not Implemented |