Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
539
matching recommendationsNAICS | 314 | Textile Product Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0115 # 10 Y:2013 | 10 | 2013 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,270 | $0 | Implemented |
NC0492 # 01 Y:2013 | 01 | 2013 | INSTALL OCCUPANCY SENSORS | $8,471 | $13,495 | Not Implemented |
NC0492 # 02 Y:2013 | 02 | 2013 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,492 | $1,140 | Implemented |
NC0492 # 03 Y:2013 | 03 | 2013 | USE PHOTOCELL CONTROLS | $259 | $250 | Not Implemented |
NC0492 # 04 Y:2013 | 04 | 2013 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,869 | $100 | Not Implemented |
NC0492 # 05 Y:2013 | 05 | 2013 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $688 | $0 | Implemented |
NC0492 # 06 Y:2013 | 06 | 2013 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $20,838 | $12,000 | Not Implemented |
NC0492 # 07 Y:2013 | 07 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $60 | $90 | Not Implemented |
NC0460 # 01 Y:2012 | 01 | 2012 | BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT | $146,006 | $260,000 | Not Implemented |
NC0460 # 02 Y:2012 | 02 | 2012 | REPAIR OR REPLACE STEAM TRAPS | $29,233 | $9,100 | Not Implemented |
NC0460 # 03 Y:2012 | 03 | 2012 | REPAIR AND ELIMINATE STEAM LEAKS | $3,142 | $2,100 | Implemented |
NC0460 # 04 Y:2012 | 04 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $43,177 | $98,248 | Not Implemented |
NC0460 # 05 Y:2012 | 05 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,871 | $80,231 | Not Implemented |
NC0460 # 06 Y:2012 | 06 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,787 | $6,902 | Not Implemented |
NC0460 # 07 Y:2012 | 07 | 2012 | INSTALL OCCUPANCY SENSORS | $42,119 | $4,405 | Not Implemented |
NC0460 # 08 Y:2012 | 08 | 2012 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $16,624 | $0 | Not Implemented |
NC0460 # 09 Y:2012 | 09 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,756 | $500 | Implemented |
NC0460 # 10 Y:2012 | 10 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,532 | $3,200 | Not Implemented |
NC0460 # 11 Y:2012 | 11 | 2012 | DEVELOP A REPAIR/REPLACE POLICY | $6,426 | $7,515 | Not Implemented |
NC0460 # 12 Y:2012 | 12 | 2012 | INSTALL / REPAIR INSULATION ON STEAM LINES | $897 | $1,290 | Not Implemented |
NC0460 # 13 Y:2012 | 13 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $119 | $11 | Not Implemented |
DL0083 # 01 Y:2012 | 01 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $10,690 | $3,000 | Not Implemented |
DL0083 # 02 Y:2012 | 02 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,150 | $100 | Not Implemented |
DL0083 # 03 Y:2012 | 03 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,950 | $100 | Implemented |
DL0083 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,960 | $5,400 | Implemented |