IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

398

matching recommendations
Reset
NAICS 315 Apparel Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MI0202 # 06 Y:2011 06 2011 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,267 $50 Implemented
DL0033 # 01 Y:2009 01 2009 USE MINIMUM STEAM OPERATING PRESSURE $1,091 $0 Implemented
DL0033 # 02 Y:2009 02 2009 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $5,409 $9,300 Implemented
DL0033 # 03 Y:2009 03 2009 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $8,789 $16,100 Implemented
DL0033 # 04 Y:2009 04 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,737 $10,000 Implemented
DL0033 # 05 Y:2009 05 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $580 $80 Implemented
DL0033 # 06 Y:2009 06 2009 UPGRADE CONTROLS ON COMPRESSORS $3,596 $12,500 Not Implemented
DL0033 # 07 Y:2009 07 2009 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $310 $150 Implemented
DL0033 # 08 Y:2009 08 2009 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS $6,433 $26,980 Implemented
DL0023 # 01 Y:2008 01 2008 TURN OFF EQUIPMENT WHEN NOT IN USE $26,000 $0 Not Implemented
DL0023 # 02 Y:2008 02 2008 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $8,300 $0 Not Implemented
DL0023 # 03 Y:2008 03 2008 TURN OFF EQUIPMENT WHEN NOT IN USE $6,900 $0 Not Implemented
DL0023 # 04 Y:2008 04 2008 RELOCATE OVEN / FURNACE TO MORE EFFICIENT LOCATION $31,000 $26,000 Not Implemented
DL0023 # 05 Y:2008 05 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,500 $22,600 Not Implemented
DL0023 # 06 Y:2008 06 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,400 $500 Not Implemented
DL0023 # 07 Y:2008 07 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $590 $150 Not Implemented
NC0381 # 01 Y:2008 01 2008 RECOVER WASTE HEAT FROM EQUIPMENT $80,420 $183,000 Not Implemented
NC0381 # 02 Y:2008 02 2008 REPLACE BOILER $34,528 $60,000 Not Implemented
NC0381 # 03 Y:2008 03 2008 ADJUST BURNERS FOR EFFICIENT OPERATION $1,430 $800 Implemented
NC0381 # 04 Y:2008 04 2008 INSULATE BARE EQUIPMENT $1,224 $1,030 Implemented
NC0381 # 05 Y:2008 05 2008 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $998 $500 Implemented
NC0381 # 06 Y:2008 06 2008 RECOVER WASTE HEAT FROM EQUIPMENT $6,183 $4,900 Not Implemented
NC0381 # 07 Y:2008 07 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,016 $100 Implemented
NC0381 # 08 Y:2008 08 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,562 $1,472 Not Implemented
NC0381 # 09 Y:2008 09 2008 DEVELOP A REPAIR/REPLACE POLICY $1,192 $1,540 Not Implemented