Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
71
matching recommendationsNAICS | 31511 | Hosiery and Sock Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0642 # 04 Y:2019 | 04 | 2019 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $16,383 | $500 | Implemented |
NC0642 # 02 Y:2019 | 02 | 2019 | INSTALL / REPAIR INSULATION ON STEAM LINES | $505 | $480 | Not Implemented |
NC0642 # 05 Y:2019 | 05 | 2019 | INSTALL OCCUPANCY SENSORS | $401 | $1,798 | Not Implemented |
NC0642 # 03 Y:2019 | 03 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,398 | $120 | Not Implemented |
NC0642 # 01 Y:2019 | 01 | 2019 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $214 | $1,000 | Not Implemented |
NC0595 # 03 Y:2017 | 03 | 2017 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $375 | $552 | Implemented |
NC0595 # 05 Y:2017 | 05 | 2017 | RECOVER WASTE HEAT FROM EQUIPMENT | $910 | $2,000 | Not Implemented |
NC0595 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $29,435 | $144,553 | Not Implemented |
NC0595 # 04 Y:2017 | 04 | 2017 | ISOLATE STEAM LINES TO AVOID HEATING AIR CONDITIONED AREAS | $3,516 | $400 | Implemented |
NC0595 # 02 Y:2017 | 02 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $896 | $100 | Implemented |
NC0547 # 08 Y:2015 | 08 | 2015 | INSTALL OCCUPANCY SENSORS | $88 | $100 | Not Implemented |
NC0547 # 02 Y:2015 | 02 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,024 | $100 | Not Implemented |
NC0547 # 07 Y:2015 | 07 | 2015 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $883 | $500 | Not Implemented |
NC0547 # 06 Y:2015 | 06 | 2015 | REPAIR OR REPLACE STEAM TRAPS | $2,433 | $11,840 | Implemented |
NC0547 # 04 Y:2015 | 04 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $675 | $1,800 | Not Implemented |
NC0547 # 13 Y:2015 | 13 | 2015 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $675 | $200 | Implemented |
NC0547 # 09 Y:2015 | 09 | 2015 | REDESIGN PROCESS | $461 | $2,000 | Not Implemented |
NC0547 # 11 Y:2015 | 11 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,688 | $281 | Implemented |
NC0547 # 12 Y:2015 | 12 | 2015 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $231 | $1,000 | Implemented |
NC0547 # 01 Y:2015 | 01 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $33,570 | $50,000 | Not Implemented |
NC0547 # 03 Y:2015 | 03 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,425 | $100 | Implemented |
NC0547 # 05 Y:2015 | 05 | 2015 | INSULATE BARE EQUIPMENT | $3,947 | $2,800 | Implemented |
NC0547 # 10 Y:2015 | 10 | 2015 | DEVELOP A REPAIR/REPLACE POLICY | $2,028 | $4,256 | Implemented |
NC0505 # 05 Y:2014 | 05 | 2014 | UPGRADE CONTROLS ON COMPRESSORS | $1,108 | $100 | Implemented |
NC0505 # 06 Y:2014 | 06 | 2014 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,874 | $200 | Implemented |