Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
226
matching recommendationsNAICS | 3152 | Cut and Sew Apparel Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UK1905 # 11 Y:2019 | 11 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,240 | $26,497 | Implemented |
UK1905 # 12 Y:2019 | 12 | 2019 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $96 | $31 | Implemented |
UK1905 # 13 Y:2019 | 13 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $305 | $33 | Implemented |
UK1905 # 14 Y:2019 | 14 | 2019 | OPTIMIZE PLANT POWER FACTOR | $1,585 | $3,010 | Not Implemented |
LE0480 # 06 Y:2019 | 06 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,546 | $107,988 | Implemented |
LE0480 # 05 Y:2019 | 05 | 2019 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,054 | $16,000 | Not Implemented |
LE0480 # 04 Y:2019 | 04 | 2019 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $19,566 | $96,000 | Not Implemented |
LE0480 # 03 Y:2019 | 03 | 2019 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $2,440 | $10,500 | Not Implemented |
LE0480 # 02 Y:2019 | 02 | 2019 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,513 | $4,500 | Not Implemented |
LE0480 # 01 Y:2019 | 01 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $418 | $35 | Implemented |
UA0204 # 01 Y:2019 | 01 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $66,234 | $104,269 | Implemented |
UA0204 # 02 Y:2019 | 02 | 2019 | INSTALL OCCUPANCY SENSORS | $238 | $145 | Not Implemented |
UA0204 # 05 Y:2019 | 05 | 2019 | INSULATE BARE EQUIPMENT | $439 | $1,082 | Implemented |
UA0204 # 03 Y:2019 | 03 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,219 | $250 | Implemented |
UA0204 # 04 Y:2019 | 04 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,537 | $1,285 | Implemented |
UK1712 # 03 Y:2017 | 03 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,140 | $11,343 | Not Implemented |
UK1712 # 04 Y:2017 | 04 | 2017 | INSTALL OCCUPANCY SENSORS | $1,664 | $1,288 | Not Implemented |
UK1712 # 07 Y:2017 | 07 | 2017 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $25,486 | $0 | Not Implemented |
UK1712 # 12 Y:2017 | 12 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $905 | $1,053 | Not Implemented |
UK1712 # 11 Y:2017 | 11 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,508 | $0 | Not Implemented |
UK1712 # 10 Y:2017 | 10 | 2017 | METER WASTE WATER | $2,076 | $253 | Not Implemented |
UK1712 # 09 Y:2017 | 09 | 2017 | METER WASTE WATER | $6,463 | $0 | Not Implemented |
UK1712 # 08 Y:2017 | 08 | 2017 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $10,498 | $0 | Not Implemented |
UK1712 # 05 Y:2017 | 05 | 2017 | USE ONLY CERTIFIED MOTOR REPAIR SHOPS | $15,253 | $0 | Not Implemented |
UK1712 # 02 Y:2017 | 02 | 2017 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $37,683 | $0 | Not Implemented |