Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

59

matching recommendations
Reset
NAICS 31521 Cut and Sew Apparel Contractors
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0824 # 05 Y:2012 05 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,772 $8,055 Implemented
OK0824 # 06 Y:2012 06 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $787 $4,095 Implemented
OK0824 # 04 Y:2012 04 2012 INSTALL OCCUPANCY SENSORS $2,183 $8,237 Not Implemented
OK0824 # 07 Y:2012 07 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $687 $1,691 Implemented
OK0824 # 03 Y:2012 03 2012 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $9,127 $23,400 Not Implemented
OK0824 # 01 Y:2012 01 2012 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $17,721 $31,152 Not Implemented
OK0824 # 09 Y:2012 09 2012 RECOVER WASTE HEAT FROM EQUIPMENT $1,249 $461 Not Implemented
OK0824 # 08 Y:2012 08 2012 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $6,045 $162,500 Implemented
OK0824 # 02 Y:2012 02 2012 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $21,096 $22,080 Not Implemented
LL0229 # 08 Y:2005 08 2005 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $2,880 $0 Not Implemented
LL0229 # 01 Y:2005 01 2005 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $14,286 $0 Not Implemented
LL0229 # 02 Y:2005 02 2005 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $8,439 $0 Not Implemented
LL0229 # 03 Y:2005 03 2005 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $4,224 $170 Implemented
LL0229 # 04 Y:2005 04 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,236 $735 Implemented
LL0229 # 05 Y:2005 05 2005 USE PHOTOCELL CONTROLS $337 $0 Not Implemented
LL0229 # 06 Y:2005 06 2005 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $1,000 $25 Implemented
LL0229 # 07 Y:2005 07 2005 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $16,500 $0 Not Implemented
MI0090 # 03 Y:2004 03 2004 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,440 $610 Not Implemented
MI0090 # 02 Y:2004 02 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $53,281 $47,250 Not Implemented
MI0090 # 01 Y:2004 01 2004 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $4,659 $600 Not Implemented
MI0090 # 04 Y:2004 04 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,398 $590 Not Implemented
MI0090 # 05 Y:2004 05 2004 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $1,667 $5,660 Not Implemented
MI0090 # 06 Y:2004 06 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,333 $112 Not Implemented
MI0090 # 07 Y:2004 07 2004 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $25,291 $6,163 Not Implemented
UM0255 # 01 Y:2004 01 2004 INSULATE BARE EQUIPMENT $10,323 $6,486 Implemented