IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,033

matching recommendations
Reset
NAICS 321 Wood Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MI0106 # 04 Y:2005 04 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,194 $862 Implemented
MI0106 # 05 Y:2005 05 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,390 $56 Implemented
MI0106 # 06 Y:2005 06 2005 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $834 $600 Not Implemented
MI0106 # 07 Y:2005 07 2005 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $756 $1,536 Not Implemented
AS0398 # 01 Y:2005 01 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,000 $2,000 Not Implemented
AS0398 # 02 Y:2005 02 2005 OPTIMIZE PLANT POWER FACTOR $749,532 $6,404,000 Not Implemented
AS0398 # 03 Y:2005 03 2005 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,293 $2,902 Not Implemented
AS0398 # 04 Y:2005 04 2005 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $811 $0 Not Implemented
AS0398 # 05 Y:2005 05 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,184 $4,984 Not Implemented
AS0398 # 06 Y:2005 06 2005 $251,744 $8,000 Not Implemented
IA0363 # 01 Y:2005 01 2005 COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER $5,128 $1,344 Not Implemented
IA0363 # 02 Y:2005 02 2005 RECOVER WASTE HEAT FROM EQUIPMENT $20,682 $12,835 Not Implemented
IA0363 # 03 Y:2005 03 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,962 $1,023 Implemented
IA0363 # 04 Y:2005 04 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,383 $15,627 Implemented
IA0363 # 05 Y:2005 05 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $971 $2,171 Not Implemented
IA0363 # 06 Y:2005 06 2005 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $20,328 $0 Implemented
IA0363 # 07 Y:2005 07 2005 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $2,742 $95 Not Implemented
IA0363 # 08 Y:2005 08 2005 INSTALL OCCUPANCY SENSORS $859 $1,617 Not Implemented
WV0311 # 01 Y:2005 01 2005 BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT $137,755 $1,055,656 Not Implemented
WV0311 # 02 Y:2005 02 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $12,082 $5,425 Implemented
WV0311 # 03 Y:2005 03 2005 DEVELOP A REPAIR/REPLACE POLICY $8,791 $869 Implemented
WV0311 # 04 Y:2005 04 2005 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $6,268 $25 Implemented
WV0311 # 05 Y:2005 05 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,074 $5,296 Implemented
WV0311 # 06 Y:2005 06 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,839 $50 Implemented
WV0311 # 07 Y:2005 07 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,113 $0 Implemented