Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

68

matching recommendations
Reset
NAICS 3211 Sawmills and Wood Preservation
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0495 # 07 Y:2006 07 2006 UPGRADE CONTROLS ON COMPRESSORS $3,900 $1,800 Implemented
OR0495 # 09 Y:2006 09 2006 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $13,300 $13,100 Implemented
OR0495 # 10 Y:2006 10 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,700 $4,700 Implemented
OR0495 # 11 Y:2006 11 2006 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $32,700 $52,000 Not Implemented
OR0495 # 12 Y:2006 12 2006 RECOVER WASTE HEAT FROM EQUIPMENT $611,000 $1,406,000 Not Implemented
OR0495 # 13 Y:2006 13 2006 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $21,000 $49,000 Implemented
OR0495 # 14 Y:2006 14 2006 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $12,900 $31,000 Not Implemented
OR0495 # 15 Y:2006 15 2006 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,500 $15,000 Not Implemented
OR0495 # 06 Y:2006 06 2006 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $5,800 $1,500 Not Implemented
OR0495 # 05 Y:2006 05 2006 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $8,900 $900 Implemented
OR0495 # 03 Y:2006 03 2006 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $15,400 $6,000 Not Implemented
OR0433 # 06 Y:2003 06 2003 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,390 $10,800 Implemented
OR0433 # 05 Y:2003 05 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $7,780 $15,000 Implemented
OR0433 # 04 Y:2003 04 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,080 $3,000 Implemented
OR0433 # 03 Y:2003 03 2003 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION $9,500 $0 Not Implemented
OR0433 # 02 Y:2003 02 2003 MODIFY PROCESS TO REDUCE MATERIAL USE/COST $78,000 $62,900 n/a
OR0433 # 01 Y:2003 01 2003 MODIFY PROCESS TO REDUCE MATERIAL USE/COST $117,000 $150,300 Implemented
OR0433 # 07 Y:2003 07 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $495 $0 Not Implemented