Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
154
matching recommendationsNAICS | 3211 | Sawmills and Wood Preservation |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0381 # 03 Y:2006 | 03 | 2006 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $3,105 | $4,018 | Not Implemented |
UF0381 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,069 | $5,892 | Not Implemented |
UF0381 # 05 Y:2006 | 05 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,966 | $334 | Implemented |
UF0381 # 06 Y:2006 | 06 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $721 | $0 | Not Implemented |
UF0381 # 07 Y:2006 | 07 | 2006 | UPGRADE OBSOLETE EQUIPMENT | $21,240 | $43,000 | Implemented |
UF0381 # 08 Y:2006 | 08 | 2006 | ELIMINATE A BY-PRODUCT | $278 | $32 | Implemented |
UF0381 # 09 Y:2006 | 09 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,919 | $0 | Implemented |
UF0381 # 10 Y:2006 | 10 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,495 | $8,880 | Implemented |
UF0381 # 11 Y:2006 | 11 | 2006 | INSTALL EQUIPMENT TO MOVE PRODUCT | $29,000 | $8,480 | Not Implemented |
UF0379 # 01 Y:2006 | 01 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $519 | $0 | Implemented |
UF0379 # 02 Y:2006 | 02 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,705 | $0 | Not Implemented |
UF0379 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,948 | $8,787 | Not Implemented |
UF0379 # 04 Y:2006 | 04 | 2006 | ISOLATE HOT OR COLD EQUIPMENT | $8,414 | $1,095 | Implemented |
UF0379 # 05 Y:2006 | 05 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $40,792 | $517 | Implemented |
UF0379 # 06 Y:2006 | 06 | 2006 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $18,041 | $44,500 | Implemented |
MS0280 # 01 Y:2005 | 01 | 2005 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $7,283 | $7,047 | Implemented |
MS0280 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,876 | $2,774 | Implemented |
MS0280 # 03 Y:2005 | 03 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,794 | $3,027 | Implemented |
MS0280 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $972 | $243 | Implemented |
MS0280 # 05 Y:2005 | 05 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $574 | $1,139 | Implemented |
MS0280 # 06 Y:2005 | 06 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $417 | $0 | Implemented |
GT0733 # 01 Y:2002 | 01 | 2002 | COMBINE UTILITY METERS | $13,100 | $1,000 | Not Implemented |
GT0733 # 02 Y:2002 | 02 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $45,343 | $49,000 | Not Implemented |
GT0733 # 03 Y:2002 | 03 | 2002 | USE WASTE HEAT STEAM FOR ABSORPTION REFRIGERATION | $56,762 | $237,300 | Not Implemented |
GT0733 # 04 Y:2002 | 04 | 2002 | IMPROVE COMBUSTION CONTROL CAPABILITY | $22,495 | $2,500 | Not Implemented |