Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
59
matching recommendationsNAICS | 3211 | Sawmills and Wood Preservation |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0238 # 05 Y:2005 | 05 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,065 | $0 | Not Implemented |
MS0280 # 05 Y:2005 | 05 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $574 | $1,139 | Implemented |
MS0280 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $972 | $243 | Implemented |
MS0280 # 03 Y:2005 | 03 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,794 | $3,027 | Implemented |
MS0280 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,876 | $2,774 | Implemented |
MS0280 # 01 Y:2005 | 01 | 2005 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $7,283 | $7,047 | Implemented |
LL0238 # 10 Y:2005 | 10 | 2005 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $7,299 | $1,000 | Implemented |
LL0238 # 09 Y:2005 | 09 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $730 | $0 | Not Implemented |
LL0238 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $285 | $0 | Not Implemented |
LL0238 # 07 Y:2005 | 07 | 2005 | USE PHOTOCELL CONTROLS | $354 | $0 | Not Implemented |
LL0238 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $480 | $0 | Not Implemented |
LL0238 # 04 Y:2005 | 04 | 2005 | INSULATE BARE EQUIPMENT | $2,207 | $500 | Implemented |
LL0238 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,179 | $1,500 | Implemented |
LL0238 # 02 Y:2005 | 02 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $47,162 | $3,000 | Implemented |
LL0238 # 01 Y:2005 | 01 | 2005 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $60,523 | $0 | Not Implemented |
MS0280 # 06 Y:2005 | 06 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $417 | $0 | Implemented |
UF0366 # 04 Y:2005 | 04 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,012 | $0 | Implemented |
UF0366 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,767 | $10,560 | Implemented |
UF0366 # 02 Y:2005 | 02 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $5,584 | $2,089 | Implemented |
UF0366 # 03 Y:2005 | 03 | 2005 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $9,884 | $784 | Implemented |
UF0366 # 06 Y:2005 | 06 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,146 | $640 | Implemented |
UF0366 # 05 Y:2005 | 05 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $33,761 | $64,979 | Implemented |
UF0366 # 09 Y:2005 | 09 | 2005 | OPTIMIZE PLANT POWER FACTOR | $39,191 | $15,000 | Implemented |
UF0366 # 07 Y:2005 | 07 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $25,852 | $4,653 | Implemented |
UF0366 # 08 Y:2005 | 08 | 2005 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $4,587 | $22,333 | Not Implemented |