IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

77

matching recommendations
Reset
NAICS 32111 Sawmills and Wood Preservation
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0444 # 01 Y:2012 01 2012 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $8,498 $8,040 Not Implemented
WV0432 # 11 Y:2011 11 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $694 $0 Not Implemented
WV0432 # 10 Y:2011 10 2011 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $762 $1,000 Implemented
WV0432 # 09 Y:2011 09 2011 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $873 $1,000 Not Implemented
WV0432 # 08 Y:2011 08 2011 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,014 $1,425 Not Implemented
WV0432 # 07 Y:2011 07 2011 DEVELOP A REPAIR/REPLACE POLICY $1,677 $1,775 Implemented
WV0432 # 06 Y:2011 06 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,989 $16,000 Not Implemented
WV0432 # 05 Y:2011 05 2011 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $2,144 $2,000 Implemented
WV0432 # 04 Y:2011 04 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,762 $290 Implemented
WV0432 # 03 Y:2011 03 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,660 $3,828 Not Implemented
WV0432 # 02 Y:2011 02 2011 OPTIMIZE PLANT POWER FACTOR $4,812 $10,750 Not Implemented
WV0432 # 01 Y:2011 01 2011 INSTALL EQUIPMENT TO UTILIZE WASTE FUEL $101,575 $193,750 Not Implemented
WV0432 # 12 Y:2011 12 2011 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $207 $25 Implemented
WV0367 # 07 Y:2008 07 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,042 $185 Not Implemented
WV0367 # 01 Y:2008 01 2008 BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT $870,056 $3,850,000 Not Implemented
WV0367 # 02 Y:2008 02 2008 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $16,386 $3,500 Implemented
WV0367 # 03 Y:2008 03 2008 DEVELOP A REPAIR/REPLACE POLICY $11,577 $1,336 Implemented
WV0367 # 04 Y:2008 04 2008 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $9,511 $0 Implemented
WV0367 # 05 Y:2008 05 2008 RECOVER WASTE HEAT FROM EQUIPMENT $2,892 $485 Not Implemented
WV0367 # 06 Y:2008 06 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,538 $0 Implemented
WV0367 # 08 Y:2008 08 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $780 $2,158 Implemented
WV0333 # 06 Y:2006 06 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $460 $0 Not Implemented
WV0333 # 05 Y:2006 05 2006 INSTALL OCCUPANCY SENSORS $397 $210 Not Implemented
WV0333 # 04 Y:2006 04 2006 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,819 $800 Implemented
WV0333 # 03 Y:2006 03 2006 DEVELOP A REPAIR/REPLACE POLICY $2,692 $544 Implemented