Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
708
matching recommendationsNAICS | 321113 | Sawmills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0432 # 11 Y:2011 | 11 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $694 | $0 | Not Implemented |
WV0432 # 12 Y:2011 | 12 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $207 | $25 | Implemented |
OR0570 # 01 Y:2011 | 01 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $19,863 | $1,120 | Implemented |
OR0570 # 02 Y:2011 | 02 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $6,640 | $2,250 | Not Implemented |
OR0570 # 03 Y:2011 | 03 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $21,600 | $12,010 | Not Implemented |
OR0570 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,900 | $17,900 | Not Implemented |
OR0570 # 05 Y:2011 | 05 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $983 | $1,000 | Not Implemented |
OR0570 # 06 Y:2011 | 06 | 2011 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $695 | $750 | Not Implemented |
OR0570 # 07 Y:2011 | 07 | 2011 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $157,400 | $191,000 | Not Implemented |
OR0570 # 08 Y:2011 | 08 | 2011 | MAKE A NEW BY-PRODUCT | $91,432 | $156,000 | Not Implemented |
OR0570 # 09 Y:2011 | 09 | 2011 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $543,000 | $1,200,000 | Not Implemented |
OR0570 # 10 Y:2011 | 10 | 2011 | INSTALL SKYLIGHTS | $2,930 | $9,050 | Not Implemented |
OR0570 # 11 Y:2011 | 11 | 2011 | OPTIMIZE PLANT POWER FACTOR | $10,100 | $51,900 | Not Implemented |
OR0571 # 01 Y:2011 | 01 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,717 | $1,120 | Not Implemented |
OR0571 # 02 Y:2011 | 02 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $13,809 | $52,890 | Implemented |
OR0571 # 03 Y:2011 | 03 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,616 | $2,200 | Implemented |
OR0571 # 04 Y:2011 | 04 | 2011 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $1,906 | $7,000 | Implemented |
OR0571 # 05 Y:2011 | 05 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $989 | $2,400 | Not Implemented |
OR0571 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,292 | $44,400 | Implemented |
OR0571 # 07 Y:2011 | 07 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,940 | $12,340 | Not Implemented |
OR0571 # 08 Y:2011 | 08 | 2011 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $285,000 | $626,000 | Not Implemented |
MS0372 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,361 | $7,887 | Not Implemented |
MS0372 # 02 Y:2011 | 02 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,674 | $1,540 | Not Implemented |
MS0372 # 03 Y:2011 | 03 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $3,255 | $903 | Not Implemented |
MS0372 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,536 | $6,412 | Not Implemented |