Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

714

matching recommendations
Reset
NAICS 321113 Sawmills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0366 # 05 Y:2005 05 2005 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $33,761 $64,979 Implemented
UF0366 # 06 Y:2005 06 2005 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,146 $640 Implemented
UF0366 # 07 Y:2005 07 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $25,852 $4,653 Implemented
UF0366 # 08 Y:2005 08 2005 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $4,587 $22,333 Not Implemented
UF0366 # 09 Y:2005 09 2005 OPTIMIZE PLANT POWER FACTOR $39,191 $15,000 Implemented
UF0366 # 10 Y:2005 10 2005 BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT $1,302,689 $10,000,000 Not Implemented
UF0366 # 11 Y:2005 11 2005 INSULATE BARE EQUIPMENT $11,128 $1,356 Implemented
UF0366 # 12 Y:2005 12 2005 INSTALL BACK-UP EQUIPMENT $569,932 $520,000 Not Implemented
UF0366 # 13 Y:2005 13 2005 IMPROVE SPACE COMFORT CONDITIONING $5,448 $24,800 Not Implemented
AS0398 # 01 Y:2005 01 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,000 $2,000 Not Implemented
AS0398 # 02 Y:2005 02 2005 OPTIMIZE PLANT POWER FACTOR $749,532 $6,404,000 Not Implemented
AS0398 # 03 Y:2005 03 2005 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,293 $2,902 Not Implemented
AS0398 # 04 Y:2005 04 2005 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $811 $0 Not Implemented
AS0398 # 05 Y:2005 05 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,184 $4,984 Not Implemented
AS0398 # 06 Y:2005 06 2005 INSTALL SENSORS TO DETECT AND AVOID JAMS $251,744 $8,000 Not Implemented
WV0311 # 01 Y:2005 01 2005 BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT $137,755 $1,055,656 Not Implemented
WV0311 # 02 Y:2005 02 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $12,082 $5,425 Implemented
WV0311 # 03 Y:2005 03 2005 DEVELOP A REPAIR/REPLACE POLICY $8,791 $869 Implemented
WV0311 # 04 Y:2005 04 2005 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $6,268 $25 Implemented
WV0311 # 05 Y:2005 05 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,074 $5,296 Implemented
WV0311 # 06 Y:2005 06 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,839 $50 Implemented
WV0311 # 07 Y:2005 07 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,113 $0 Implemented
WV0311 # 08 Y:2005 08 2005 REPAIR OR REPLACE STEAM TRAPS $1,475 $1,000 Implemented
WV0311 # 09 Y:2005 09 2005 INSULATE BARE EQUIPMENT $1,173 $885 Implemented
WV0311 # 10 Y:2005 10 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $905 $980 Not Implemented