Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

129

matching recommendations
Reset
NAICS 321113 Sawmills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UA3031 # 04 Y:2013 04 2013 INSTALL / REPAIR INSULATION ON STEAM LINES $174 $3,355 Not Implemented
UA3031 # 05 Y:2013 05 2013 INSTALL / REPAIR INSULATION ON STEAM LINES $85 $609 Not Implemented
UA3031 # 06 Y:2013 06 2013 MODIFY STARTUP/SHUTDOWN TIMES $15,087 $0 Not Implemented
UA3031 # 07 Y:2013 07 2013 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,270 $1,654 Implemented
UA3031 # 08 Y:2013 08 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,244 $4,074 Implemented
UA3031 # 09 Y:2013 09 2013 INSTALL OCCUPANCY SENSORS $362 $763 Not Implemented
UA0035 # 01 Y:2009 01 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,780 $1,500 Implemented
UA0035 # 02 Y:2009 02 2009 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $8,120 $0 Not Implemented
UA0035 # 03 Y:2009 03 2009 RECOVER WASTE HEAT FROM EQUIPMENT $11,800 $2,900 Not Implemented
UA0035 # 04 Y:2009 04 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,882 $87,077 Implemented
UA0035 # 05 Y:2009 05 2009 USE PHOTOCELL CONTROLS $1,846 $1,782 Not Implemented
UA0035 # 06 Y:2009 06 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $899 $5,448 Implemented
UA0035 # 07 Y:2009 07 2009 INSTALL / REPAIR INSULATION ON STEAM LINES $3,983 $2,478 Implemented
UA0035 # 08 Y:2009 08 2009 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $129,337 $0 Implemented
UA0035 # 09 Y:2009 09 2009 INSTALL TIMERS AND/OR THERMOSTATS $3,810 $2,210 Implemented
UA0035 # 10 Y:2009 10 2009 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $40,375 $77,000 Implemented
UA0035 # 11 Y:2009 11 2009 UPGRADE CONTROLS ON COMPRESSORS $26,217 $10,000 Not Implemented
UA0012 # 01 Y:2007 01 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,155 $700 Implemented
UA0012 # 02 Y:2007 02 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,165 $0 Implemented
UA0012 # 03 Y:2007 03 2007 BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT $1,063,171 $5,532,000 Not Implemented
UA0012 # 04 Y:2007 04 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,620 $9,817 Not Implemented
UA0012 # 05 Y:2007 05 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $737 $7,504 Not Implemented
UA0012 # 06 Y:2007 06 2007 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,429 $1,230 Not Implemented
UF0381 # 01 Y:2006 01 2006 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $3,568 $0 Not Implemented
UF0381 # 02 Y:2006 02 2006 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $4,916 $715 Implemented