Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
78
matching recommendationsNAICS | 3219 | Other Wood Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0464 # 05 Y:2016 | 05 | 2016 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $2,107 | $7,900 | Implemented |
UM0464 # 04 Y:2016 | 04 | 2016 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $736 | $150 | Implemented |
UM0464 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,786 | $3,794 | Implemented |
UM0464 # 02 Y:2016 | 02 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,842 | $5,500 | Not Implemented |
UM0464 # 01 Y:2016 | 01 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $361 | $2,000 | Not Implemented |
UD0915 # 02 Y:2014 | 02 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,184 | $1,200 | Implemented |
UD0915 # 11 Y:2014 | 11 | 2014 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $7,301 | $0 | Not Implemented |
UD0915 # 10 Y:2014 | 10 | 2014 | ADD AREA LIGHTING SWITCHES | $117 | $0 | Not Implemented |
UD0915 # 08 Y:2014 | 08 | 2014 | COVER OPEN TANKS | $14,519 | $39,186 | Not Implemented |
UD0915 # 07 Y:2014 | 07 | 2014 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $993 | $2,575 | Not Implemented |
UD0915 # 06 Y:2014 | 06 | 2014 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $17,210 | $23,600 | Not Implemented |
UD0915 # 05 Y:2014 | 05 | 2014 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $1,180 | $700 | Not Implemented |
UD0915 # 04 Y:2014 | 04 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,815 | $100 | Implemented |
UD0915 # 03 Y:2014 | 03 | 2014 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $7,714 | $1,800 | Implemented |
UD0915 # 01 Y:2014 | 01 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,262 | $0 | Implemented |
UD0915 # 09 Y:2014 | 09 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $129,321 | $377,745 | Not Implemented |
WV0466 # 03 Y:2013 | 03 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $11,380 | $0 | Not Implemented |
WV0466 # 09 Y:2013 | 09 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,160 | $488 | Implemented |
WV0466 # 08 Y:2013 | 08 | 2013 | IMPROVE LUBRICATION PRACTICES | $2,167 | $1,000 | Implemented |
WV0466 # 01 Y:2013 | 01 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $73,182 | $32,900 | Not Implemented |
WV0466 # 05 Y:2013 | 05 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $12,752 | $3,840 | Not Implemented |
WV0466 # 06 Y:2013 | 06 | 2013 | OPTIMIZE PLANT POWER FACTOR | $3,614 | $5,600 | Not Implemented |
WV0466 # 02 Y:2013 | 02 | 2013 | INSULATE BARE EQUIPMENT | $15,207 | $35,976 | Implemented |
WV0466 # 04 Y:2013 | 04 | 2013 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $11,321 | $1,000 | Not Implemented |
WV0466 # 07 Y:2013 | 07 | 2013 | BURN WASTE OIL FOR HEAT | $2,530 | $4,000 | Not Implemented |