IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

674

matching recommendations
Reset
NAICS 3221 Pulp, Paper, and Paperboard Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0473 # 01 Y:2016 01 2016 REPAIR OR REPLACE STEAM TRAPS $80,322 $10,300 Implemented
BD0473 # 02 Y:2016 02 2016 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $28,176 $50,000 Not Implemented
BD0473 # 03 Y:2016 03 2016 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $21,188 $60,260 Not Implemented
BD0473 # 04 Y:2016 04 2016 INSTALL OCCUPANCY SENSORS $4,714 $1,650 Not Implemented
BD0473 # 05 Y:2016 05 2016 ADJUST / MAINTAIN FORK LIFT TRUCKS FOR MOST EFFICIENT OPERATION $3,820 $15,000 Not Implemented
BD0473 # 06 Y:2016 06 2016 USE SYNTHETIC LUBRICANT $2,870 $1,000 Implemented
BD0473 # 07 Y:2016 07 2016 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,273 $25 Not Implemented
BD0473 # 08 Y:2016 08 2016 USE PHOTOCELL CONTROLS $2,036 $6,825 Not Implemented
BD0473 # 09 Y:2016 09 2016 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,722 $1,000 Not Implemented
BD0473 # 10 Y:2016 10 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,414 $2,000 Implemented
BD0473 # 11 Y:2016 11 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,387 $414 Implemented
BD0473 # 12 Y:2016 12 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $456 $400 Implemented
UA0151 # 01 Y:2015 01 2015 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $107,877 $42,000 Implemented
UA0151 # 02 Y:2015 02 2015 INCREASE AMOUNT OF CONDENSATE RETURNED $48,953 $110,000 Implemented
UA0151 # 03 Y:2015 03 2015 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $182,046 $500,000 Not Implemented
UA0151 # 04 Y:2015 04 2015 USE STEAM PRESSURE REDUCTION TO GENERATE POWER $25,377 $93,550 Not Implemented
UA0151 # 05 Y:2015 05 2015 USE STEAM PRESSURE REDUCTION TO GENERATE POWER $23,156 $85,365 Not Implemented
OK0911 # 08 Y:2015 08 2015 MINIMIZE WATER USAGE $136,438 $968,000 Not Implemented
OK0911 # 09 Y:2015 09 2015 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $85 $420 Not Implemented
OK0911 # 07 Y:2015 07 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,129 $4,880 Not Implemented
OK0911 # 06 Y:2015 06 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,343 $37,638 Not Implemented
OK0911 # 05 Y:2015 05 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,030 $3,797 Not Implemented
OK0911 # 04 Y:2015 04 2015 REPLACE BOILER $501,021 $1,650,000 Not Implemented
OK0911 # 03 Y:2015 03 2015 INSTALL / REPAIR INSULATION ON STEAM LINES $12,634 $2,848 Implemented
OK0911 # 02 Y:2015 02 2015 REPAIR AND ELIMINATE STEAM LEAKS $7,790 $400 Implemented