Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
34
matching recommendationsNAICS | 3221 | Pulp, Paper, and Paperboard Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0078 # 01 Y:2011 | 01 | 2011 | REPLACE BOILER | $123,207 | $900,000 | Not Implemented |
DL0078 # 04 Y:2011 | 04 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $57,285 | $28,500 | Not Implemented |
DL0078 # 07 Y:2011 | 07 | 2011 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $77,835 | $42,650 | Implemented |
DL0078 # 08 Y:2011 | 08 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $23,761 | $22,500 | Not Implemented |
DL0078 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $33,872 | $165,720 | Not Implemented |
DL0078 # 03 Y:2011 | 03 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $30,553 | $42,800 | Not Implemented |
DL0078 # 06 Y:2011 | 06 | 2011 | INSTALL SPECTRAL REFLECTORS / DELAMP | $14,637 | $800 | Not Implemented |
DL0078 # 02 Y:2011 | 02 | 2011 | USE RADIANT HEATER FOR SPOT HEATING | $191,452 | $500,000 | Not Implemented |
MA0684 # 04 Y:2011 | 04 | 2011 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,744 | $0 | Not Implemented |
MA0684 # 07 Y:2011 | 07 | 2011 | INSULATE BARE EQUIPMENT | $1,402 | $2,100 | Implemented |
MA0684 # 06 Y:2011 | 06 | 2011 | INSTALL OCCUPANCY SENSORS | $2,502 | $2,200 | Implemented |
MA0684 # 05 Y:2011 | 05 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $3,360 | $10,625 | Not Implemented |
MA0684 # 03 Y:2011 | 03 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $11,358 | $15,000 | Implemented |
MA0684 # 02 Y:2011 | 02 | 2011 | REDUCE VENTILATION AIR | $14,891 | $3,700 | Implemented |
MA0684 # 01 Y:2011 | 01 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $23,122 | $40,000 | Implemented |
MAS013 # 01 Y:2011 | 01 | 2011 | UPGRADE OBSOLETE EQUIPMENT | $27,730 | $42,112 | Not Implemented |
MAS013 # 02 Y:2011 | 02 | 2011 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $21,255 | $20,475 | Implemented |
MAS013 # 03 Y:2011 | 03 | 2011 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $12,053 | $0 | Implemented |
MAS013 # 04 Y:2011 | 04 | 2011 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $7,289 | $15,000 | Not Implemented |
MAS013 # 05 Y:2011 | 05 | 2011 | INSULATE BARE EQUIPMENT | $3,878 | $3,600 | Implemented |
MAS013 # 06 Y:2011 | 06 | 2011 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $3,738 | $8,000 | Implemented |
MAS013 # 07 Y:2011 | 07 | 2011 | TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS | $2,115 | $150 | Implemented |
MAS013 # 08 Y:2011 | 08 | 2011 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $942 | $5,000 | Not Implemented |
MAS013 # 09 Y:2011 | 09 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $784 | $3,500 | Implemented |
MA0675 # 04 Y:2011 | 04 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,736 | $23,800 | Not Implemented |