IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

38

matching recommendations
Reset
NAICS 322110 Pulp Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UA0234 # 04 Y:2020 04 2020 USE PHOTOCELL CONTROLS $34 $112 Not Implemented
UA0234 # 03 Y:2020 03 2020 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $638 $850 Implemented
UA0234 # 02 Y:2020 02 2020 OPTIMIZE PLANT POWER FACTOR $1,608 $7,769 Not Implemented
UA0234 # 01 Y:2020 01 2020 MODIFY STARTUP/SHUTDOWN TIMES $17,505 $0 Implemented
WV0580 # 06 Y:2019 06 2019 REPAIR OR REPLACE STEAM TRAPS $1,791 $5,731 Implemented
WV0580 # 05 Y:2019 05 2019 INSULATE BARE EQUIPMENT $2,238 $2,550 Implemented
WV0580 # 04 Y:2019 04 2019 RECOVER WASTE HEAT FROM EQUIPMENT $8,437 $15,360 Implemented
WV0580 # 03 Y:2019 03 2019 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR $52,590 $160,314 Not Implemented
WV0580 # 02 Y:2019 02 2019 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $143,962 $6,000 Implemented
WV0580 # 01 Y:2019 01 2019 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $265,061 $31,000 Not Implemented
UW0048 # 01 Y:2011 01 2011 IMPROVE COMBUSTION CONTROL CAPABILITY $308,364 $40,543 Not Implemented
UW0048 # 02 Y:2011 02 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,203 $2,440 Not Implemented
UW0030 # 01 Y:2009 01 2009 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $134,729 $705,718 Not Implemented
UW0030 # 02 Y:2009 02 2009 KEEP BOILER TUBES CLEAN $115,460 $50,000 Not Implemented
UW0030 # 03 Y:2009 03 2009 OPTIMIZE PLANT POWER FACTOR $74,218 $166,366 Not Implemented
MA0637 # 11 Y:2008 11 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,939 $10,400 Not Implemented
MA0637 # 02 Y:2008 02 2008 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $180,534 $80,000 Implemented
MA0637 # 03 Y:2008 03 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $169,795 $80,000 Not Implemented
MA0637 # 04 Y:2008 04 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $58,079 $54,000 Not Implemented
MA0637 # 05 Y:2008 05 2008 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $29,950 $27,000 Not Implemented
MA0637 # 06 Y:2008 06 2008 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR $24,017 $14,000 Implemented
MA0637 # 07 Y:2008 07 2008 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $20,954 $41,000 Not Implemented
MA0637 # 08 Y:2008 08 2008 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $18,443 $16,000 Not Implemented
MA0637 # 01 Y:2008 01 2008 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $254,315 $250,000 Not Implemented
MA0637 # 09 Y:2008 09 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $8,892 $15,000 Not Implemented