Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
29
matching recommendationsNAICS | 322121 | Paper (except Newsprint) Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0585 # 02 Y:2005 | 02 | 2005 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $91,755 | $254,400 | Not Implemented |
MA0585 # 03 Y:2005 | 03 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $73,100 | $37,300 | Implemented |
MA0585 # 04 Y:2005 | 04 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $54,416 | $37,300 | Implemented |
MA0585 # 05 Y:2005 | 05 | 2005 | USE MINIMUM STEAM OPERATING PRESSURE | $29,239 | $23,014 | Implemented |
MA0585 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $28,480 | $78,770 | Implemented |
MA0585 # 07 Y:2005 | 07 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,353 | $9,225 | Implemented |
MA0585 # 08 Y:2005 | 08 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,385 | $5,300 | Implemented |
MA0585 # 09 Y:2005 | 09 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,037 | $5,300 | Implemented |
MA0585 # 01 Y:2005 | 01 | 2005 | BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT | $112,569 | $254,000 | Not Implemented |
NC0328 # 06 Y:2005 | 06 | 2005 | USE PHOTOCELL CONTROLS | $115 | $165 | Implemented |
NC0328 # 05 Y:2005 | 05 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $11,954 | $480 | Implemented |
NC0328 # 04 Y:2005 | 04 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $10,481 | $3,035 | Not Implemented |
NC0328 # 02 Y:2005 | 02 | 2005 | BURN A LESS EXPENSIVE GRADE OF FUEL | $113,412 | $10,000 | Not Implemented |
NC0328 # 01 Y:2005 | 01 | 2005 | ADJUST BURNERS FOR EFFICIENT OPERATION | $8,068 | $6,225 | Not Implemented |
NC0328 # 03 Y:2005 | 03 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,962 | $7,002 | Not Implemented |
SU0213 # 14 Y:2005 | 14 | 2005 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $294 | $676 | Not Implemented |
SU0213 # 13 Y:2005 | 13 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $345 | $446 | Not Implemented |
SU0213 # 12 Y:2005 | 12 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $153,447 | $120,000 | Implemented |
SU0213 # 11 Y:2005 | 11 | 2005 | INSTALL OCCUPANCY SENSORS | $694 | $381 | Not Implemented |
SU0213 # 10 Y:2005 | 10 | 2005 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $70,404 | $35,100 | Implemented |
SU0213 # 09 Y:2005 | 09 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $22,902 | $5,674 | Implemented |
SU0213 # 08 Y:2005 | 08 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,629 | $494 | Implemented |
SU0213 # 07 Y:2005 | 07 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,469 | $901 | Implemented |
SU0213 # 06 Y:2005 | 06 | 2005 | USE SYNTHETIC LUBRICANT | $23,908 | $1,000 | Implemented |
SU0213 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $977 | $0 | Implemented |