Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
17
matching recommendationsNAICS | 322130 | Paperboard Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0332 # 04 Y:2006 | 04 | 2006 | REPLACE BOILER | $683,163 | $1,003,522 | Not Implemented |
SF0332 # 03 Y:2006 | 03 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,653 | $238 | Not Implemented |
SF0332 # 02 Y:2006 | 02 | 2006 | INSULATE BARE EQUIPMENT | $66,216 | $5,557 | Implemented |
SF0332 # 01 Y:2006 | 01 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $10,511 | $0 | Implemented |
IC0114 # 09 Y:2006 | 09 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $10,414 | $65,273 | Implemented |
IC0114 # 13 Y:2006 | 13 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,383 | $9,400 | Implemented |
IC0114 # 12 Y:2006 | 12 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $2,000 | $2,800 | Implemented |
IC0114 # 11 Y:2006 | 11 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,400 | $1,200 | Implemented |
IC0114 # 10 Y:2006 | 10 | 2006 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $2,000 | $8,400 | Implemented |
IC0114 # 01 Y:2006 | 01 | 2006 | INSTALL TURBULATORS | $42,000 | $7,500 | Not Implemented |
IC0114 # 08 Y:2006 | 08 | 2006 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $91,228 | $834,000 | Not Implemented |
IC0114 # 07 Y:2006 | 07 | 2006 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $93,057 | $456,000 | Not Implemented |
IC0114 # 06 Y:2006 | 06 | 2006 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $4,216 | $5,280 | Not Implemented |
IC0114 # 05 Y:2006 | 05 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,400 | $16,800 | Not Implemented |
IC0114 # 04 Y:2006 | 04 | 2006 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $175,000 | $120,400 | Not Implemented |
IC0114 # 03 Y:2006 | 03 | 2006 | MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT | $19,000 | $63,000 | Implemented |
IC0114 # 02 Y:2006 | 02 | 2006 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $16,000 | $84,000 | Not Implemented |