Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
66
matching recommendationsNAICS | 322211 | Corrugated and Solid Fiber Box Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0612 # 01 Y:2024 | 01 | 2024 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $402,389 | $1,529,500 | n/a |
UF0612 # 03 Y:2024 | 03 | 2024 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $45,994 | $20,000 | n/a |
UF0612 # 10 Y:2024 | 10 | 2024 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $5,066 | $2,320 | n/a |
UF0612 # 09 Y:2024 | 09 | 2024 | UPGRADE CONTROLS ON COMPRESSORS | $5,236 | $6,087 | n/a |
UF0612 # 08 Y:2024 | 08 | 2024 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $7,481 | $5,900 | n/a |
UF0612 # 02 Y:2024 | 02 | 2024 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $55,068 | $30,945 | n/a |
UF0612 # 04 Y:2024 | 04 | 2024 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $44,735 | $34,020 | n/a |
UF0612 # 05 Y:2024 | 05 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,865 | $8,523 | n/a |
UF0612 # 06 Y:2024 | 06 | 2024 | INSTALL TURBULATORS | $13,749 | $3,750 | n/a |
UF0612 # 07 Y:2024 | 07 | 2024 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $9,443 | $21,120 | n/a |
UF0391 # 14 Y:2006 | 14 | 2006 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $83,200 | $5,350 | Not Implemented |
UF0391 # 02 Y:2006 | 02 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,932 | $0 | Implemented |
UF0391 # 12 Y:2006 | 12 | 2006 | USE PHOTOCELL CONTROLS | $1,978 | $30 | Implemented |
UF0391 # 13 Y:2006 | 13 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $63,455 | $0 | Not Implemented |
UF0391 # 11 Y:2006 | 11 | 2006 | INSTALL OCCUPANCY SENSORS | $286 | $228 | Not Implemented |
UF0391 # 16 Y:2006 | 16 | 2006 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $10,320 | $0 | Not Implemented |
UF0391 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,054 | $403 | Implemented |
UF0391 # 04 Y:2006 | 04 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $8,241 | $404 | Implemented |
UF0391 # 01 Y:2006 | 01 | 2006 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $24,522 | $41,500 | Not Implemented |
UF0391 # 15 Y:2006 | 15 | 2006 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $17,472 | $0 | Not Implemented |
UF0391 # 05 Y:2006 | 05 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,679 | $0 | Implemented |
UF0391 # 08 Y:2006 | 08 | 2006 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $803 | $0 | Implemented |
UF0391 # 10 Y:2006 | 10 | 2006 | USE OPTIMUM THICKNESS INSULATION | $324 | $372 | Not Implemented |
UF0391 # 06 Y:2006 | 06 | 2006 | CLOSE OFF UNNEEDED STEAM LINES | $9,659 | $0 | Implemented |
UF0391 # 07 Y:2006 | 07 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,307 | $10,651 | Not Implemented |