Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
30
matching recommendationsNAICS | 322211 | Corrugated and Solid Fiber Box Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0350 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,959 | $88,072 | Implemented |
WV0350 # 17 Y:2006 | 17 | 2006 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $333 | $0 | Not Implemented |
WV0350 # 16 Y:2006 | 16 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $438 | $250 | Not Implemented |
WV0350 # 15 Y:2006 | 15 | 2006 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $454 | $640 | Not Implemented |
WV0350 # 14 Y:2006 | 14 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,174 | $375 | Implemented |
WV0350 # 13 Y:2006 | 13 | 2006 | DEVELOP A REPAIR/REPLACE POLICY | $1,612 | $735 | Implemented |
WV0350 # 12 Y:2006 | 12 | 2006 | BURN WASTE OIL FOR HEAT | $2,316 | $1,180 | Not Implemented |
WV0350 # 11 Y:2006 | 11 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,824 | $330 | Not Implemented |
WV0350 # 10 Y:2006 | 10 | 2006 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $3,679 | $1,000 | Implemented |
WV0350 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,103 | $8,181 | Implemented |
WV0350 # 08 Y:2006 | 08 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,275 | $60 | Not Implemented |
WV0350 # 07 Y:2006 | 07 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,063 | $0 | Implemented |
WV0350 # 06 Y:2006 | 06 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,094 | $1,000 | Implemented |
WV0350 # 05 Y:2006 | 05 | 2006 | REPAIR OR REPLACE STEAM TRAPS | $14,508 | $2,500 | Implemented |
WV0350 # 04 Y:2006 | 04 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,173 | $16,600 | Not Implemented |
WV0350 # 02 Y:2006 | 02 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $24,663 | $23,600 | Implemented |
WV0350 # 01 Y:2006 | 01 | 2006 | INSULATE BARE EQUIPMENT | $44,076 | $2,440 | Implemented |
LE0231 # 01 Y:2006 | 01 | 2006 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $140,853 | $660,000 | Not Implemented |
LE0231 # 13 Y:2006 | 13 | 2006 | INSTALL OCCUPANCY SENSORS | $3,076 | $300 | Not Implemented |
LE0231 # 12 Y:2006 | 12 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,229 | $500 | Not Implemented |
LE0231 # 11 Y:2006 | 11 | 2006 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,485 | $3,600 | Implemented |
LE0231 # 10 Y:2006 | 10 | 2006 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,915 | $189 | Implemented |
LE0231 # 09 Y:2006 | 09 | 2006 | IMPROVE COMBUSTION CONTROL CAPABILITY | $7,881 | $2,500 | Implemented |
LE0231 # 08 Y:2006 | 08 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,127 | $400 | Implemented |
LE0231 # 07 Y:2006 | 07 | 2006 | INSULATE BARE EQUIPMENT | $16,394 | $13,060 | Not Implemented |