IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

22

matching recommendations
Reset
NAICS 32229 Other Converted Paper Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0494 # 09 Y:2020 09 2020 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $411 $833 Not Implemented
SU0494 # 08 Y:2020 08 2020 ELIMINATE/REDUCE AN OPERATION $1,957 $1,928 Not Implemented
SU0494 # 07 Y:2020 07 2020 REDUCE VENTILATION AIR $1,099 $917 Not Implemented
SU0494 # 06 Y:2020 06 2020 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $18,491 $13,991 Implemented
SU0494 # 05 Y:2020 05 2020 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $749 $532 Not Implemented
SU0494 # 04 Y:2020 04 2020 INSTALL OCCUPANCY SENSORS $2,182 $766 Not Implemented
SU0494 # 03 Y:2020 03 2020 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $1,238 $0 Implemented
SU0494 # 02 Y:2020 02 2020 PAY BILLS ON TIME TO AVOID LATE FEES $172 $0 Implemented
SU0494 # 01 Y:2020 01 2020 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $831 $0 Not Implemented
SU0337 # 06 Y:2013 06 2013 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $290 $596 Not Implemented
SU0337 # 07 Y:2013 07 2013 OPTIMIZE PLANT POWER FACTOR $6,664 $33,352 Not Implemented
SU0337 # 05 Y:2013 05 2013 INSTALL / REPAIR INSULATION ON STEAM LINES $693 $895 Implemented
SU0337 # 04 Y:2013 04 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $469 $346 Implemented
SU0337 # 03 Y:2013 03 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,655 $2,760 Implemented
SU0337 # 02 Y:2013 02 2013 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,848 $517 Implemented
SU0337 # 01 Y:2013 01 2013 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $85 $0 Not Implemented
SU0207 # 01 Y:2005 01 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $206 $0 Implemented
SU0207 # 06 Y:2005 06 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $55 $92 Implemented
SU0207 # 05 Y:2005 05 2005 ADJUST VENTS TO MINIMIZE ENERGY USE $21,600 $21,422 Not Implemented
SU0207 # 04 Y:2005 04 2005 USE SYNTHETIC LUBRICANT $2,489 $2,000 Not Implemented
SU0207 # 03 Y:2005 03 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,791 $477 Implemented
SU0207 # 02 Y:2005 02 2005 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $2,133 $0 Not Implemented