Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,874

matching recommendations
Reset
NAICS 32311 Printing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0483 # 02 Y:2017 02 2017 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $13,305 $5,000 n/a
UM0483 # 03 Y:2017 03 2017 INSTALL OCCUPANCY SENSORS $860 $1,650 n/a
UM0483 # 04 Y:2017 04 2017 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,643 $3,700 n/a
WM0101 # 01 Y:2017 01 2017 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $25,590 $22,000 Not Implemented
WM0101 # 02 Y:2017 02 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,976 $25,932 Not Implemented
WM0101 # 03 Y:2017 03 2017 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $2,523 $260 Not Implemented
WM0101 # 04 Y:2017 04 2017 INSTALL OCCUPANCY SENSORS $2,778 $1,590 Not Implemented
WM0101 # 05 Y:2017 05 2017 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,320 $6,300 Not Implemented
WM0101 # 06 Y:2017 06 2017 USE PHOTOCELL CONTROLS $545 $885 Not Implemented
WM0101 # 07 Y:2017 07 2017 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT $251 $200 Implemented
WM0101 # 08 Y:2017 08 2017 SHADE WINDOWS FROM SUMMER SUN $245 $210 Not Implemented
WM0100 # 01 Y:2017 01 2017 MAKE ICE DURING OFF PEAK HOURS FOR COOLING $42,285 $81,148 Not Implemented
WM0100 # 02 Y:2017 02 2017 USE SYNTHETIC LUBRICANT $9,329 $21,800 Not Implemented
WM0100 # 03 Y:2017 03 2017 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,307 $4,000 Not Implemented
WM0100 # 04 Y:2017 04 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,055 $7,820 Not Implemented
WM0100 # 05 Y:2017 05 2017 INSTALL OCCUPANCY SENSORS $1,541 $0 Not Implemented
WM0100 # 06 Y:2017 06 2017 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,107 $2,250 Not Implemented
WM0100 # 07 Y:2017 07 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $454 $1,600 Not Implemented
UK1611 # 01 Y:2016 01 2016 PREHEAT COMBUSTION AIR WITH WASTE HEAT $36,855 $47,256 Not Implemented
UK1611 # 02 Y:2016 02 2016 PREHEAT COMBUSTION AIR WITH WASTE HEAT $21,755 $55,980 Not Implemented
UK1611 # 03 Y:2016 03 2016 INSTALL AN UNINTERUPTABLE POWER SUPPLY $12,000 $3,000 Implemented
UK1611 # 04 Y:2016 04 2016 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $840 $0 Implemented
UK1611 # 05 Y:2016 05 2016 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $5,216 $1,200 Implemented
UK1611 # 06 Y:2016 06 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,906 $2,760 Implemented
UK1611 # 07 Y:2016 07 2016 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $735 $0 Implemented