Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
93
matching recommendationsNAICS | 32311 | Printing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0717 # 05 Y:2005 | 05 | 2005 | INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION | $12,000 | $2,300 | Not Implemented |
UD0717 # 06 Y:2005 | 06 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,225 | $0 | Implemented |
UD0717 # 13 Y:2005 | 13 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $441 | $882 | Not Implemented |
UD0717 # 12 Y:2005 | 12 | 2005 | INSULATE BARE EQUIPMENT | $670 | $780 | Not Implemented |
UD0717 # 11 Y:2005 | 11 | 2005 | USE OPTIMUM THICKNESS INSULATION | $1,314 | $1,962 | Not Implemented |
UD0717 # 10 Y:2005 | 10 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,845 | $0 | Not Implemented |
UD0717 # 09 Y:2005 | 09 | 2005 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $3,658 | $2,526 | Implemented |
UD0717 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,553 | $11,448 | Implemented |
UD0703 # 05 Y:2004 | 05 | 2004 | $1,200 | $0 | Not Implemented | |
UD0703 # 02 Y:2004 | 02 | 2004 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $5,110 | $0 | Implemented |
UD0703 # 04 Y:2004 | 04 | 2004 | REDUCE OR ELIMINATE WASTE | $1,365 | $1,960 | Implemented |
UD0703 # 03 Y:2004 | 03 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,733 | $5,215 | Not Implemented |
UD0703 # 09 Y:2004 | 09 | 2004 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $356 | $522 | Not Implemented |
UD0703 # 06 Y:2004 | 06 | 2004 | DISCONNECT BALLASTS | $762 | $235 | Not Implemented |
UD0703 # 07 Y:2004 | 07 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $520 | $0 | Not Implemented |
UD0703 # 08 Y:2004 | 08 | 2004 | DISCONNECT BALLASTS | $392 | $206 | Implemented |
UD0703 # 01 Y:2004 | 01 | 2004 | REDUCE SCRAP PRODUCTION | $45,630 | $650 | Implemented |
UD0703 # 10 Y:2004 | 10 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $289 | $126 | Implemented |