Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
125
matching recommendationsNAICS | 323113 | Commercial Screen Printing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0731 # 10 Y:2005 | 10 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,953 | $15,113 | Implemented |
UD0731 # 11 Y:2005 | 11 | 2005 | CHANGE ZONE REHEAT COILS TO VARIABLE AIR VOLUME BOXES | $4,182 | $0 | Not Implemented |
UD0731 # 12 Y:2005 | 12 | 2005 | REDUCE VENTILATION AIR | $1,932 | $119 | Not Implemented |
UD0731 # 13 Y:2005 | 13 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $1,894 | $0 | Implemented |
UD0731 # 14 Y:2005 | 14 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $1,010 | $0 | Implemented |
UD0731 # 15 Y:2005 | 15 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $622 | $0 | Implemented |
UD0731 # 16 Y:2005 | 16 | 2005 | DISCONNECT BALLASTS | $440 | $66 | Not Implemented |
IC0097 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,330 | $700 | Implemented |
IC0097 # 02 Y:2005 | 02 | 2005 | ISOLATE HOT OR COLD EQUIPMENT | $1,426 | $3,768 | Not Implemented |
IC0097 # 03 Y:2005 | 03 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,092 | $41,838 | Implemented |
IC0097 # 04 Y:2005 | 04 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,151 | $5,789 | Not Implemented |
IC0097 # 05 Y:2005 | 05 | 2005 | USE OPTIMUM TEMPERATURE | $163 | $1,044 | Not Implemented |
UF0321 # 01 Y:2003 | 01 | 2003 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $7,390 | $2,948 | Not Implemented |
UF0321 # 02 Y:2003 | 02 | 2003 | INSULATE BARE EQUIPMENT | $1,530 | $868 | Not Implemented |
UF0321 # 03 Y:2003 | 03 | 2003 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $17,331 | $45,500 | Implemented |
UF0321 # 04 Y:2003 | 04 | 2003 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $7,451 | $740 | Not Implemented |
UF0321 # 05 Y:2003 | 05 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,598 | $376 | Not Implemented |
UF0321 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,755 | $852 | Not Implemented |
UF0321 # 07 Y:2003 | 07 | 2003 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $15,954 | $436 | Implemented |
UF0321 # 08 Y:2003 | 08 | 2003 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $18,000 | $4,000 | Implemented |
WI0441 # 01 Y:2003 | 01 | 2003 | INCREASE USE OF AUTOMATION | $66,563 | $30,000 | Not Implemented |
WI0441 # 02 Y:2003 | 02 | 2003 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $5,650 | $16,800 | Implemented |
WI0441 # 03 Y:2003 | 03 | 2003 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $2,550 | $0 | Implemented |
WI0441 # 04 Y:2003 | 04 | 2003 | USE POWER DURING OFF-PEAK PERIODS | $1,486 | $0 | Not Implemented |
WI0441 # 05 Y:2003 | 05 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $168 | $640 | Not Implemented |