Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
57
matching recommendationsNAICS | 324 | Petroleum and Coal Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA3008 # 03 Y:2010 | 03 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,470 | $2,149 | Implemented |
UA3008 # 08 Y:2010 | 08 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,004 | $16,161 | Not Implemented |
UA3008 # 02 Y:2010 | 02 | 2010 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $5,598 | $17,500 | Implemented |
UA3008 # 04 Y:2010 | 04 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $12,090 | $20,526 | Not Implemented |
UA3008 # 07 Y:2010 | 07 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,619 | $1,500 | Not Implemented |
UA3008 # 05 Y:2010 | 05 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $497 | $340 | Not Implemented |
UA3008 # 01 Y:2010 | 01 | 2010 | REPAIR AND ELIMINATE STEAM LEAKS | $6,109 | $337 | Implemented |
UA3008 # 06 Y:2010 | 06 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,485 | $640 | Not Implemented |
MZ0054 # 02 Y:2010 | 02 | 2010 | INSULATE BARE EQUIPMENT | $3,852 | $940 | Not Implemented |
MZ0054 # 03 Y:2010 | 03 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $24,485 | $30,000 | Not Implemented |
MZ0054 # 04 Y:2010 | 04 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $60,827 | $30,000 | Not Implemented |
MZ0054 # 05 Y:2010 | 05 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,942 | $17,975 | Not Implemented |
MZ0054 # 01 Y:2010 | 01 | 2010 | INSULATE BARE EQUIPMENT | $2,366 | $1,054 | Not Implemented |
MZ0054 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,678 | $2,840 | Not Implemented |
CO0637 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,650 | $20,950 | Implemented |
CO0637 # 01 Y:2010 | 01 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $13,860 | $24,000 | Implemented |
CO0637 # 02 Y:2010 | 02 | 2010 | INSULATE BARE EQUIPMENT | $3,450 | $1,790 | Not Implemented |
CO0637 # 07 Y:2010 | 07 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $220 | $900 | Not Implemented |
CO0637 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $430 | $450 | Not Implemented |
CO0637 # 05 Y:2010 | 05 | 2010 | USE SOLAR HEAT TO MAKE ELECTRICTY | $1,560 | $20,500 | Not Implemented |
CO0637 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,200 | $460 | Implemented |
DL0056 # 08 Y:2010 | 08 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $35,000 | $94,500 | Not Implemented |
DL0056 # 05 Y:2010 | 05 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,000 | $300 | Implemented |
DL0056 # 06 Y:2010 | 06 | 2010 | USE OPTIMUM TEMPERATURE | $7,644 | $100 | Implemented |
DL0056 # 07 Y:2010 | 07 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $5,100 | $100 | Not Implemented |