IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,503

matching recommendations
Reset
NAICS 325 Chemical Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0348 # 03 Y:2010 03 2010 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT $29,394 $103,215 Not Implemented
MS0348 # 04 Y:2010 04 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,319 $50,244 Not Implemented
MS0348 # 05 Y:2010 05 2010 INSTALL OCCUPANCY SENSORS $5,041 $300 Not Implemented
MS0348 # 06 Y:2010 06 2010 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,658 $2,310 Not Implemented
MS0348 # 07 Y:2010 07 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,423 $378 Not Implemented
WV0397 # 10 Y:2009 10 2009 REPAIR OR REPLACE STEAM TRAPS $7,120 $5,500 Implemented
WV0397 # 11 Y:2009 11 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,792 $19,960 Implemented
WV0397 # 01 Y:2009 01 2009 REDUCE VENTILATION AIR $153,645 $145,000 Not Implemented
WV0397 # 02 Y:2009 02 2009 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $81,057 $131,239 Not Implemented
WV0397 # 03 Y:2009 03 2009 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $77,885 $17,000 Not Implemented
WV0397 # 04 Y:2009 04 2009 OPERATE BOILERS ON HIGH FIRE SETTING $56,916 $80,000 Not Implemented
WV0397 # 05 Y:2009 05 2009 OPTIMIZE PLANT POWER FACTOR $40,984 $44,000 Not Implemented
WV0397 # 06 Y:2009 06 2009 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $26,130 $36,900 Not Implemented
WV0397 # 07 Y:2009 07 2009 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $17,728 $0 Implemented
WV0397 # 08 Y:2009 08 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $15,726 $1,000 Implemented
WV0397 # 09 Y:2009 09 2009 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $9,377 $49,300 Not Implemented
UM0359 # 01 Y:2009 01 2009 REDUCE VENTILATION AIR $20,146 $500 Implemented
UM0359 # 02 Y:2009 02 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,026 $50,000 Implemented
UM0359 # 03 Y:2009 03 2009 LOWER COMPRESSOR PRESSURE THROUGH A/C SYSTEM MODIFICATION $13,963 $400 Implemented
UM0359 # 04 Y:2009 04 2009 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $11,980 $9,000 Not Implemented
UM0359 # 05 Y:2009 05 2009 INSTALL STORM WINDOWS AND DOORS $6,298 $24,510 Implemented
UM0359 # 06 Y:2009 06 2009 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $2,724 $7,574 Not Implemented
UM0359 # 07 Y:2009 07 2009 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,630 $5,000 Not Implemented
UM0359 # 08 Y:2009 08 2009 RECOVER WASTE HEAT FROM EQUIPMENT $1,620 $10,000 Implemented
UM0359 # 09 Y:2009 09 2009 INSTALL OCCUPANCY SENSORS $1,161 $30,000 Implemented