Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,556
matching recommendationsNAICS | 325 | Chemical Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0658 # 06 Y:2010 | 06 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,142 | $18,500 | Implemented |
MA0658 # 07 Y:2010 | 07 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,702 | $3,170 | Implemented |
MA0658 # 08 Y:2010 | 08 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,482 | $3,175 | Not Implemented |
MA0658 # 09 Y:2010 | 09 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,225 | $4,295 | Implemented |
MA0658 # 10 Y:2010 | 10 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,172 | $5,170 | Implemented |
GT0871 # 01 Y:2010 | 01 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,860 | $768 | Implemented |
GT0871 # 02 Y:2010 | 02 | 2010 | INCREASE AMOUNT OF CONDENSATE RETURNED | $20,114 | $23,200 | Not Implemented |
GT0871 # 03 Y:2010 | 03 | 2010 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $40,118 | $23,620 | Implemented |
GT0871 # 04 Y:2010 | 04 | 2010 | INSTALL DE-AERATOR IN PLACE OF CONDENSATE TANK | $119,576 | $25,000 | Not Implemented |
GT0871 # 05 Y:2010 | 05 | 2010 | UPGRADE CONTROLS ON COMPRESSORS | $3,635 | $22,000 | Not Implemented |
GT0871 # 06 Y:2010 | 06 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $16,535 | $11,000 | Not Implemented |
GT0871 # 07 Y:2010 | 07 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,563 | $17,696 | Implemented |
GT0871 # 08 Y:2010 | 08 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,500 | $12,000 | Not Implemented |
LL0325 # 01 Y:2010 | 01 | 2010 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $40,139 | $3,000 | Implemented |
LL0325 # 02 Y:2010 | 02 | 2010 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,692 | $30 | Implemented |
LL0325 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,166 | $595 | Not Implemented |
LL0325 # 04 Y:2010 | 04 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,019 | $1,265 | Implemented |
LL0325 # 05 Y:2010 | 05 | 2010 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $803 | $623 | Not Implemented |
LL0325 # 06 Y:2010 | 06 | 2010 | INSTALL OCCUPANCY SENSORS | $114 | $120 | Not Implemented |
LL0325 # 07 Y:2010 | 07 | 2010 | USE PHOTOCELL CONTROLS | $39 | $30 | Not Implemented |
OK0786 # 01 Y:2010 | 01 | 2010 | OPERATE BOILERS ON HIGH FIRE SETTING | $2,348 | $24,000 | Not Implemented |
OK0786 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $106 | $604 | Not Implemented |
OK0786 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $453 | $3,410 | Not Implemented |
OK0786 # 04 Y:2010 | 04 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $854 | $0 | Implemented |
OK0786 # 05 Y:2010 | 05 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $1,491 | $465 | Implemented |