Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,556
matching recommendationsNAICS | 325 | Chemical Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0336 # 04 Y:2006 | 04 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,827 | $5,934 | Not Implemented |
SF0336 # 05 Y:2006 | 05 | 2006 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $22,164 | $15,000 | Not Implemented |
SF0336 # 06 Y:2006 | 06 | 2006 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $31 | $29,700 | Not Implemented |
SF0336 # 07 Y:2006 | 07 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $883 | $4,374 | Not Implemented |
SF0336 # 08 Y:2006 | 08 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $872 | $2,849 | Not Implemented |
SF0336 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2 | $7,040 | Implemented |
SF0336 # 10 Y:2006 | 10 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $234 | $557 | Implemented |
SF0336 # 11 Y:2006 | 11 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $955 | $2,480 | Implemented |
SF0336 # 12 Y:2006 | 12 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,076 | $16,625 | Implemented |
SF0336 # 13 Y:2006 | 13 | 2006 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $327 | $6,381 | Implemented |
NC0345 # 01 Y:2006 | 01 | 2006 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $8,498 | $4,000 | Not Implemented |
NC0345 # 02 Y:2006 | 02 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,488 | $8,000 | Not Implemented |
NC0345 # 03 Y:2006 | 03 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,461 | $4,000 | Not Implemented |
NC0345 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,300 | $50 | Not Implemented |
NC0345 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,538 | $2,465 | Not Implemented |
NC0345 # 06 Y:2006 | 06 | 2006 | USE PHOTOCELL CONTROLS | $147 | $95 | Not Implemented |
NC0345 # 07 Y:2006 | 07 | 2006 | USE PHOTOCELL CONTROLS | $291 | $95 | Implemented |
LE0247 # 01 Y:2006 | 01 | 2006 | REPLACE BOILER | $115,080 | $223,000 | Not Implemented |
LE0247 # 02 Y:2006 | 02 | 2006 | REVISE RAW MATERIAL SPECS | $106,250 | $60,000 | Not Implemented |
LE0247 # 03 Y:2006 | 03 | 2006 | REPAIR OR REPLACE STEAM TRAPS | $26,312 | $16,000 | Not Implemented |
LE0247 # 04 Y:2006 | 04 | 2006 | ADOPT IN-HOUSE MATERIAL GENERATION | $24,012 | $20,000 | Implemented |
LE0247 # 05 Y:2006 | 05 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $23,245 | $15,000 | Not Implemented |
LE0247 # 06 Y:2006 | 06 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $11,646 | $2,500 | Implemented |
LE0247 # 07 Y:2006 | 07 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,225 | $1,152 | Implemented |
LE0247 # 08 Y:2006 | 08 | 2006 | INSTALL OCCUPANCY SENSORS | $1,181 | $300 | Not Implemented |