Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,556
matching recommendationsNAICS | 325 | Chemical Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0237 # 06 Y:2006 | 06 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,658 | $3,000 | Not Implemented |
LE0237 # 07 Y:2006 | 07 | 2006 | INSTALL OCCUPANCY SENSORS | $3,162 | $900 | Implemented |
GT0822 # 01 Y:2006 | 01 | 2006 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $22,995 | $640 | Implemented |
GT0822 # 02 Y:2006 | 02 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,292 | $10,800 | Not Implemented |
GT0822 # 03 Y:2006 | 03 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $97,628 | $18,865 | Implemented |
GT0822 # 04 Y:2006 | 04 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,620 | $850 | Not Implemented |
GT0822 # 05 Y:2006 | 05 | 2006 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $60,069 | $87,937 | Not Implemented |
GT0822 # 06 Y:2006 | 06 | 2006 | COMBINE UTILITY METERS | $4,697 | $0 | Not Implemented |
GT0822 # 07 Y:2006 | 07 | 2006 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $450,000 | $20,000 | Implemented |
GT0820 # 01 Y:2006 | 01 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $204,303 | $0 | Not Implemented |
GT0820 # 02 Y:2006 | 02 | 2006 | USE PHOTOCELL CONTROLS | $15,359 | $12,000 | Not Implemented |
GT0820 # 03 Y:2006 | 03 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,732 | $1,390 | Not Implemented |
GT0820 # 04 Y:2006 | 04 | 2006 | USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS | $4,073 | $10,200 | Not Implemented |
GT0820 # 05 Y:2006 | 05 | 2006 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $6,650 | $5,952 | Not Implemented |
LL0245 # 01 Y:2006 | 01 | 2006 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $3,334,582 | $60,000 | Implemented |
LL0245 # 02 Y:2006 | 02 | 2006 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $2,369,946 | $5,024,000 | Not Implemented |
LL0245 # 03 Y:2006 | 03 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $323,360 | $14,100 | Implemented |
LL0245 # 04 Y:2006 | 04 | 2006 | INSULATE BARE EQUIPMENT | $185,638 | $4,644 | Not Implemented |
LL0245 # 05 Y:2006 | 05 | 2006 | USE PHOTOCELL CONTROLS | $45,203 | $6,300 | Implemented |
LL0245 # 06 Y:2006 | 06 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $32,924 | $11,000 | Not Implemented |
LL0245 # 07 Y:2006 | 07 | 2006 | INSULATE BARE EQUIPMENT | $12,103 | $1,218 | Implemented |
LL0245 # 08 Y:2006 | 08 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,818 | $3,500 | Not Implemented |
LL0245 # 09 Y:2006 | 09 | 2006 | INSTALL OCCUPANCY SENSORS | $1,010 | $2,813 | Not Implemented |
WV0341 # 01 Y:2006 | 01 | 2006 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $7,713 | $2,370 | Implemented |
WV0341 # 02 Y:2006 | 02 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,073 | $1,800 | Implemented |