Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
55
matching recommendationsNAICS | 3251 | Basic Chemical Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0387 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,457 | $3,064 | Implemented |
BD0387 # 01 Y:2011 | 01 | 2011 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $25,233 | $21,500 | Implemented |
BD0387 # 06 Y:2011 | 06 | 2011 | REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE | $374,556 | $995,000 | Not Implemented |
BD0387 # 05 Y:2011 | 05 | 2011 | MINIMIZE WATER USAGE | $2,025 | $1,600 | Not Implemented |
BD0387 # 04 Y:2011 | 04 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,318 | $200 | Not Implemented |
BD0387 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $1,861 | $600 | Implemented |
IC0112 # 05 Y:2006 | 05 | 2006 | INSTALL DESICCANT HUMIDITY CONTROL SYSTEM | $28,585 | $165,480 | Not Implemented |
IC0112 # 08 Y:2006 | 08 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,114 | $0 | Implemented |
IC0112 # 07 Y:2006 | 07 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,753 | $2,300 | Implemented |
IC0112 # 01 Y:2006 | 01 | 2006 | REPLACE BOILER | $300,562 | $414,240 | Not Implemented |
IC0112 # 03 Y:2006 | 03 | 2006 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $44,296 | $145,126 | Implemented |
IC0112 # 04 Y:2006 | 04 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $42,495 | $66,129 | Not Implemented |
IC0112 # 06 Y:2006 | 06 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $48,787 | $157,465 | Implemented |
IC0112 # 02 Y:2006 | 02 | 2006 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $57,168 | $11,016 | Implemented |
IC0111 # 07 Y:2006 | 07 | 2006 | USE MINIMUM STEAM OPERATING PRESSURE | $22,776 | $0 | Implemented |
IC0111 # 09 Y:2006 | 09 | 2006 | REPAIR OR REPLACE STEAM TRAPS | $158,427 | $5,152 | Implemented |
IC0111 # 06 Y:2006 | 06 | 2006 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $57,000 | $36,000 | Not Implemented |
IC0111 # 05 Y:2006 | 05 | 2006 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $11,047 | $30,000 | Not Implemented |
IC0111 # 04 Y:2006 | 04 | 2006 | INCREASE AMOUNT OF CONDENSATE RETURNED | $93,000 | $235,998 | Implemented |
IC0111 # 03 Y:2006 | 03 | 2006 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $186,788 | $135,156 | Not Implemented |
IC0111 # 02 Y:2006 | 02 | 2006 | REPLACE ELECTRIC MOTORS WITH BACK PRESSURE STEAM TURBINES AND USE EXHAUST STEAM FOR PROCESS HEAT | $95,000 | $442,680 | Not Implemented |
IC0111 # 01 Y:2006 | 01 | 2006 | REPLACE STEAM JETS ON VACUUM SYSTEM WITH ELECTRIC MOTOR DRIVEN VACUUM PUMPS | $803,012 | $258,000 | Implemented |
IC0111 # 11 Y:2006 | 11 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $23,163 | $1,600 | Implemented |
IC0111 # 12 Y:2006 | 12 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $45,671 | $195,432 | Implemented |
IC0111 # 10 Y:2006 | 10 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $17,406 | $19,704 | Implemented |