Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,050
matching recommendationsNAICS | 3251 | Basic Chemical Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0371 # 10 Y:2014 | 10 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $941 | $1,000 | Implemented |
LE0371 # 11 Y:2014 | 11 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,799 | $12,800 | Not Implemented |
LE0371 # 12 Y:2014 | 12 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,819 | $4,118 | Not Implemented |
LE0371 # 13 Y:2014 | 13 | 2014 | REPAIR AND ELIMINATE STEAM LEAKS | $3,675 | $1,285 | Not Implemented |
LE0371 # 14 Y:2014 | 14 | 2014 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $1,091 | $4,140 | Implemented |
LE0371 # 15 Y:2014 | 15 | 2014 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $4,748 | $21,000 | Not Implemented |
LE0371 # 16 Y:2014 | 16 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,704 | $12,536 | Not Implemented |
LE0371 # 17 Y:2014 | 17 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $71 | $350 | Not Implemented |
SF0442 # 01 Y:2014 | 01 | 2014 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,021 | $0 | Implemented |
SF0442 # 02 Y:2014 | 02 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,864 | $2,722 | Implemented |
SF0442 # 03 Y:2014 | 03 | 2014 | ADD AREA LIGHTING SWITCHES | $409 | $252 | Not Implemented |
SF0442 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,082 | $12,459 | Implemented |
SF0442 # 05 Y:2014 | 05 | 2014 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $231 | $1,559 | Implemented |
SF0442 # 06 Y:2014 | 06 | 2014 | USE SOLAR HEAT TO MAKE ELECTRICTY | $14,162 | $173,094 | Not Implemented |
OR0611 # 01 Y:2013 | 01 | 2013 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $3,437 | $0 | Not Implemented |
OR0611 # 02 Y:2013 | 02 | 2013 | UPGRADE CONTROLS ON COMPRESSORS | $8,684 | $5,600 | Not Implemented |
OR0611 # 03 Y:2013 | 03 | 2013 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $7,909 | $37,830 | Not Implemented |
OR0611 # 04 Y:2013 | 04 | 2013 | UPGRADE OBSOLETE EQUIPMENT | $5,340 | $11,938 | Not Implemented |
OR0611 # 05 Y:2013 | 05 | 2013 | INSTALL OCCUPANCY SENSORS | $2,436 | $2,159 | Not Implemented |
OR0611 # 06 Y:2013 | 06 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,410 | $3,724 | Not Implemented |
OR0611 # 07 Y:2013 | 07 | 2013 | AVOID CONTAMINATION OF END PIECES AND REUSE AS FEED STOCK | $1,200 | $5,464 | Not Implemented |
OR0611 # 08 Y:2013 | 08 | 2013 | INSULATE BARE EQUIPMENT | $922 | $2,134 | Not Implemented |
NC0490 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,689 | $7,449 | Not Implemented |
NC0490 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,248 | $4,989 | Implemented |
NC0490 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $213 | $381 | Implemented |