Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
23
matching recommendationsNAICS | 325199 | All Other Basic Organic Chemical Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0134 # 08 Y:2014 | 08 | 2014 | METER WASTE WATER | $8,610 | $8,200 | Implemented |
DL0134 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,200 | $13,590 | Not Implemented |
DL0134 # 06 Y:2014 | 06 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,090 | $10,500 | Not Implemented |
DL0134 # 05 Y:2014 | 05 | 2014 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $54,210 | $28,110 | Not Implemented |
DL0134 # 01 Y:2014 | 01 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $36,000 | $33,600 | Implemented |
DL0134 # 02 Y:2014 | 02 | 2014 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $41,430 | $54,000 | Implemented |
DL0134 # 03 Y:2014 | 03 | 2014 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $16,580 | $0 | Implemented |
DL0134 # 04 Y:2014 | 04 | 2014 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $4,630 | $5,700 | Not Implemented |
DL0082 # 02 Y:2012 | 02 | 2012 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $18,536 | $46,000 | Not Implemented |
DL0082 # 05 Y:2012 | 05 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,636 | $2,100 | Not Implemented |
DL0082 # 04 Y:2012 | 04 | 2012 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $716 | $90 | Implemented |
DL0082 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,641 | $1,330 | Implemented |
DL0082 # 01 Y:2012 | 01 | 2012 | REDUCE VENTILATION AIR | $64,179 | $280,000 | Not Implemented |
LE0239 # 01 Y:2006 | 01 | 2006 | INCREASE AMOUNT OF CONDENSATE RETURNED | $392,390 | $95,000 | Not Implemented |
LE0239 # 02 Y:2006 | 02 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $280,038 | $31,000 | Not Implemented |
LE0239 # 03 Y:2006 | 03 | 2006 | INCREASE AMOUNT OF CONDENSATE RETURNED | $204,235 | $200,000 | Not Implemented |
LE0239 # 04 Y:2006 | 04 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $115,069 | $20,000 | Not Implemented |
LE0239 # 05 Y:2006 | 05 | 2006 | COVER OPEN TANKS | $23,836 | $30,000 | Not Implemented |
LE0239 # 06 Y:2006 | 06 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,473 | $28,000 | Not Implemented |
LE0239 # 07 Y:2006 | 07 | 2006 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $10,599 | $7,500 | Not Implemented |
LE0239 # 08 Y:2006 | 08 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,312 | $2,528 | Not Implemented |
LE0239 # 09 Y:2006 | 09 | 2006 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $1,132 | $6,000 | Not Implemented |
LE0239 # 10 Y:2006 | 10 | 2006 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $355 | $500 | Not Implemented |