IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

58

matching recommendations
Reset
NAICS 3252 Resin, Synthetic Rubber, and Artificial Synthetic Fibers and Filaments Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TA0101 # 01 Y:2005 01 2005 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $18,313 $0 Implemented
TA0101 # 04 Y:2005 04 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,140 $0 Implemented
TA0101 # 09 Y:2005 09 2005 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $275 $0 Not Implemented
TA0101 # 05 Y:2005 05 2005 DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING $1,595 $0 Implemented
TA0101 # 06 Y:2005 06 2005 INSULATE BARE EQUIPMENT $800 $85 Implemented
TA0101 # 07 Y:2005 07 2005 INSULATE BARE EQUIPMENT $665 $200 Implemented
TA0101 # 02 Y:2005 02 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,480 $190 Implemented
TA0101 # 10 Y:2005 10 2005 INSULATE BARE EQUIPMENT $255 $360 Implemented
TA0101 # 03 Y:2005 03 2005 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $2,970 $0 Implemented
TA0101 # 08 Y:2005 08 2005 INSTALL OCCUPANCY SENSORS $395 $100 Implemented
IC0105 # 02 Y:2005 02 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $7,211 $2,000 Implemented
IC0105 # 08 Y:2005 08 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,344 $13,017 Not Implemented
IC0105 # 07 Y:2005 07 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $255 $714 Not Implemented
IC0105 # 06 Y:2005 06 2005 INSTALL OCCUPANCY SENSORS $94 $713 Not Implemented
IC0105 # 05 Y:2005 05 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,728 $42,000 Not Implemented
IC0105 # 04 Y:2005 04 2005 INSTALL DE-AERATOR IN PLACE OF CONDENSATE TANK $12,910 $900 Not Implemented
IC0105 # 03 Y:2005 03 2005 REPAIR AND ELIMINATE STEAM LEAKS $17,271 $3,900 Implemented
IC0105 # 01 Y:2005 01 2005 INSTALL / REPAIR INSULATION ON STEAM LINES $60,808 $100,000 Implemented
AM0494 # 12 Y:2005 12 2005 ELIMINATE LEAKS IN WATER LINES AND VALVES $230 $200 Implemented
AM0494 # 11 Y:2005 11 2005 USE SYNTHETIC LUBRICANT $570 $0 Not Implemented
AM0494 # 10 Y:2005 10 2005 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $770 $660 Implemented
AM0494 # 08 Y:2005 08 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,330 $12 Implemented
AM0494 # 06 Y:2005 06 2005 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,440 $760 Not Implemented
AM0494 # 05 Y:2005 05 2005 OPTIMIZE PLANT POWER FACTOR $3,870 $9,160 Implemented
AM0494 # 02 Y:2005 02 2005 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $5,880 $540 Implemented