Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,034
matching recommendationsNAICS | 32521 | Resin and Synthetic Rubber Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0182 # 05 Y:2011 | 05 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $2,734 | $11,001 | Not Implemented |
IC0182 # 06 Y:2011 | 06 | 2011 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,070 | $0 | Not Implemented |
IC0182 # 07 Y:2011 | 07 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,314 | $5,489 | Not Implemented |
IC0182 # 08 Y:2011 | 08 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $950 | $311 | Not Implemented |
IC0182 # 09 Y:2011 | 09 | 2011 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $2,442 | $311 | Not Implemented |
IC0182 # 10 Y:2011 | 10 | 2011 | INSTALL AUTOMATIC STACK DAMPER | $5,217 | $50,324 | Not Implemented |
IC0182 # 11 Y:2011 | 11 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,294 | $921 | Not Implemented |
IC0182 # 12 Y:2011 | 12 | 2011 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $1,314 | $1,318 | Not Implemented |
IC0182 # 13 Y:2011 | 13 | 2011 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $379 | $379 | Not Implemented |
IC0182 # 14 Y:2011 | 14 | 2011 | OPTIMIZE PLANT POWER FACTOR | $3,378 | $20,932 | Not Implemented |
IC0182 # 15 Y:2011 | 15 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $110 | $0 | Not Implemented |
UM0386 # 01 Y:2011 | 01 | 2011 | INSTALL OCCUPANCY SENSORS | $3,851 | $2,100 | Not Implemented |
UM0386 # 02 Y:2011 | 02 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $2,043 | $3,615 | Implemented |
UM0386 # 03 Y:2011 | 03 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,167 | $1,000 | Implemented |
UM0386 # 04 Y:2011 | 04 | 2011 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $2,885 | $18,495 | Not Implemented |
UM0386 # 05 Y:2011 | 05 | 2011 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,336 | $2,471 | Implemented |
UM0386 # 06 Y:2011 | 06 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,285 | $1,000 | Not Implemented |
UM0386 # 07 Y:2011 | 07 | 2011 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $982 | $10 | Not Implemented |
UM0386 # 08 Y:2011 | 08 | 2011 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $16,332 | $92,500 | Not Implemented |
WV0422 # 01 Y:2011 | 01 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $29,044 | $18,250 | Not Implemented |
WV0422 # 02 Y:2011 | 02 | 2011 | CHANGE ZONE REHEAT COILS TO VARIABLE AIR VOLUME BOXES | $9,494 | $17,598 | Not Implemented |
WV0422 # 03 Y:2011 | 03 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,167 | $1,000 | Implemented |
WV0422 # 04 Y:2011 | 04 | 2011 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $3,049 | $2,000 | Implemented |
WV0422 # 05 Y:2011 | 05 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $2,822 | $1,150 | Implemented |
WV0422 # 06 Y:2011 | 06 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,969 | $920 | Not Implemented |