Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
17
matching recommendationsNAICS | 32521 | Resin and Synthetic Rubber Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK1048 # 05 Y:2021 | 05 | 2021 | OPTIMIZE PLANT POWER FACTOR | $22,294 | $15,000 | Not Implemented |
OK1048 # 04 Y:2021 | 04 | 2021 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,153 | $4,000 | Not Implemented |
OK1048 # 03 Y:2021 | 03 | 2021 | INSTALL OCCUPANCY SENSORS | $2,257 | $3,150 | Implemented |
OK1048 # 02 Y:2021 | 02 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,475 | $13,356 | Implemented |
OK1048 # 01 Y:2021 | 01 | 2021 | REPAIR AND ELIMINATE STEAM LEAKS | $37,041 | $2,860 | Implemented |
OK0739 # 04 Y:2006 | 04 | 2006 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $3,011 | $390 | Not Implemented |
OK0739 # 07 Y:2006 | 07 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,734 | $9,485 | Not Implemented |
OK0739 # 06 Y:2006 | 06 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,587 | $191 | Implemented |
OK0739 # 05 Y:2006 | 05 | 2006 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $5,090 | $7,944 | Implemented |
OK0739 # 03 Y:2006 | 03 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $139,230 | $39,852 | Not Implemented |
OK0739 # 02 Y:2006 | 02 | 2006 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $156,872 | $2,175,000 | Not Implemented |
OK0739 # 01 Y:2006 | 01 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,798 | $9,750 | Implemented |
OK0737 # 01 Y:2006 | 01 | 2006 | USE MINIMUM STEAM OPERATING PRESSURE | $22,707 | $1,420 | Not Implemented |
OK0737 # 05 Y:2006 | 05 | 2006 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $28,248 | $15,000 | Not Implemented |
OK0737 # 04 Y:2006 | 04 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $30,440 | $19,260 | Not Implemented |
OK0737 # 03 Y:2006 | 03 | 2006 | REPAIR OR REPLACE STEAM TRAPS | $92,687 | $1,025 | Not Implemented |
OK0737 # 02 Y:2006 | 02 | 2006 | INCREASE AMOUNT OF CONDENSATE RETURNED | $7,798 | $11,625 | Not Implemented |