Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
31
matching recommendationsNAICS | 32521 | Resin and Synthetic Rubber Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0959 # 06 Y:2021 | 06 | 2021 | USE SOLAR HEAT TO MAKE ELECTRICTY | $37,630 | $621,000 | Not Implemented |
GT0959 # 05 Y:2021 | 05 | 2021 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $6,169 | $23,000 | Not Implemented |
GT0959 # 04 Y:2021 | 04 | 2021 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $170 | $315 | Implemented |
GT0959 # 03 Y:2021 | 03 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,641 | $1,850 | Implemented |
GT0959 # 02 Y:2021 | 02 | 2021 | INSTALL TIMERS AND/OR THERMOSTATS | $184 | $50 | Implemented |
GT0959 # 01 Y:2021 | 01 | 2021 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $11,495 | $800 | Implemented |
TT0258 # 03 Y:2021 | 03 | 2021 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,751 | $37,500 | Not Implemented |
TT0258 # 02 Y:2021 | 02 | 2021 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,627 | $25,000 | Not Implemented |
TT0258 # 01 Y:2021 | 01 | 2021 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $65,709 | $230,400 | Not Implemented |
TT0258 # 04 Y:2021 | 04 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,652 | $4,000 | Not Implemented |
TT0258 # 05 Y:2021 | 05 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,092 | $10,000 | Not Implemented |
TT0258 # 07 Y:2021 | 07 | 2021 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $1,108 | $5,000 | Not Implemented |
TT0258 # 08 Y:2021 | 08 | 2021 | DEVELOP A REPAIR/REPLACE POLICY | $445 | $0 | Not Implemented |
TT0258 # 06 Y:2021 | 06 | 2021 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $1,703 | $7,500 | Not Implemented |
BS0148 # 04 Y:2021 | 04 | 2021 | INSTALL OCCUPANCY SENSORS | $1,298 | $600 | Not Implemented |
BS0148 # 03 Y:2021 | 03 | 2021 | INSTALL / REPAIR INSULATION ON STEAM LINES | $445 | $649 | Not Implemented |
BS0148 # 02 Y:2021 | 02 | 2021 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,112 | $50,404 | Not Implemented |
BS0148 # 01 Y:2021 | 01 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $39,220 | $24,000 | Not Implemented |
OK1048 # 01 Y:2021 | 01 | 2021 | REPAIR AND ELIMINATE STEAM LEAKS | $37,041 | $2,860 | Implemented |
OK1048 # 02 Y:2021 | 02 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,475 | $13,356 | Implemented |
OK1048 # 03 Y:2021 | 03 | 2021 | INSTALL OCCUPANCY SENSORS | $2,257 | $3,150 | Implemented |
OK1048 # 04 Y:2021 | 04 | 2021 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,153 | $4,000 | Not Implemented |
OK1048 # 05 Y:2021 | 05 | 2021 | OPTIMIZE PLANT POWER FACTOR | $22,294 | $15,000 | Not Implemented |
CL2108 # 07 Y:2021 | 07 | 2021 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $947 | $0 | n/a |
CL2108 # 02 Y:2021 | 02 | 2021 | INSTALL OCCUPANCY SENSORS | $1,049 | $3,565 | n/a |