Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
115
matching recommendationsNAICS | 325220 | Artificial and Synthetic Fibers and Filaments Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0938 # 03 Y:2019 | 03 | 2019 | INSULATE BARE EQUIPMENT | $1,868 | $1,016 | Not Implemented |
GT0938 # 02 Y:2019 | 02 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $16,092 | $3,500 | Implemented |
GT0938 # 01 Y:2019 | 01 | 2019 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $14,349 | $2,000 | Implemented |
GT0933 # 04 Y:2019 | 04 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $32,851 | $41,392 | Implemented |
GT0933 # 01 Y:2019 | 01 | 2019 | INSTALL HEAT PIPES / RAISE COOLING SETPOINT | $10,455 | $250 | Implemented |
GT0933 # 02 Y:2019 | 02 | 2019 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $23,854 | $13,713 | Not Implemented |
GT0933 # 03 Y:2019 | 03 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $199 | $213 | Implemented |
GT0933 # 05 Y:2019 | 05 | 2019 | INSULATE BARE EQUIPMENT | $4,386 | $6,741 | Not Implemented |
GT0933 # 06 Y:2019 | 06 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,768 | $9,616 | Implemented |
GT0933 # 07 Y:2019 | 07 | 2019 | USE SOLAR HEAT TO MAKE ELECTRICTY | $71,526 | $507,835 | Not Implemented |
NC0559 # 15 Y:2016 | 15 | 2016 | DEVELOP A REPAIR/REPLACE POLICY | $2,264 | $4,256 | Implemented |
NC0559 # 14 Y:2016 | 14 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,366 | $1,800 | Not Implemented |
NC0559 # 13 Y:2016 | 13 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,085 | $1,000 | Implemented |
NC0559 # 01 Y:2016 | 01 | 2016 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $109,787 | $1,000 | Implemented |
NC0559 # 10 Y:2016 | 10 | 2016 | USE PHOTOCELL CONTROLS | $1,339 | $1,600 | Implemented |
NC0559 # 11 Y:2016 | 11 | 2016 | INSTALL OCCUPANCY SENSORS | $494 | $347 | Implemented |
NC0559 # 06 Y:2016 | 06 | 2016 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $9,950 | $25,000 | Implemented |
NC0559 # 08 Y:2016 | 08 | 2016 | REPAIR AND ELIMINATE STEAM LEAKS | $7,231 | $2,000 | Implemented |
NC0559 # 09 Y:2016 | 09 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,038 | $320 | Implemented |
NC0559 # 07 Y:2016 | 07 | 2016 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $34,146 | $10,000 | Implemented |
NC0559 # 02 Y:2016 | 02 | 2016 | REPLACE ELECTRIC MOTORS WITH BACK PRESSURE STEAM TURBINES AND USE EXHAUST STEAM FOR PROCESS HEAT | $28,202 | $75,000 | Not Implemented |
NC0559 # 04 Y:2016 | 04 | 2016 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $5,720 | $10,000 | Not Implemented |
NC0559 # 05 Y:2016 | 05 | 2016 | FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM | $20,410 | $15,050 | Not Implemented |
NC0559 # 03 Y:2016 | 03 | 2016 | REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS | $4,003 | $1,000 | Implemented |
NC0559 # 12 Y:2016 | 12 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,545 | $8,000 | Not Implemented |