Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2016 |
Principal Product | Carbon fiber |
NAICS | 325220 - Artificial and Synthetic Fibers and Filaments Manufacturing |
SIC | 2823 - Cellulosic Manmade Fibers |
Sales | $10,000,000-$50,000,000 |
# of Employees | 120 |
Plant Area (Sq.Ft.) | 250,000 |
Annual Production | 1,000,000 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | SC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,638,639 | 42,868,867 | kWh | $0.04 |
Electricity Demand | $643,355 | 67,211 | kW-months/year | $9.57 |
Natural Gas | $906,898 | 198,587 | MMBtu | $4.57 |
TOTAL ENERGY COSTS | $3,188,892 | |||
RECOMMENDED SAVINGS* | $241,580 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $180,337 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $109,787 Cost: $1,000 |
$109,787 | - | - | - | - | - | - | - | - | - |
$109,787 - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3411 REPLACE ELECTRIC MOTORS WITH BACK PRESSURE STEAM TURBINES AND USE EXHAUST STEAM FOR PROCESS HEAT |
Savings: $28,202 Cost: $75,000 |
$33,329 | 872,496 | $11,438 | 1,195 | $(-16,565) | (-3,625) | - | - | - | - |
$33,329 872,496 kWh |
$11,438 1,195 kW-months/year |
$(-16,565) (-3,625) MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.5122 REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS |
Savings: $4,003 Cost: $1,000 |
$374 | 9,802 | $129 | 13 | - | - | - | - | $3,500 | - |
$374 9,802 kWh |
$129 13 kW-months/year |
- - MMBtu |
- - $ |
$3,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $5,720 Cost: $10,000 |
$4,258 | 111,480 | $1,462 | 153 | - | - | - | - | - | - |
$4,258 111,480 kWh |
$1,462 153 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2127 FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM |
Savings: $20,410 Cost: $15,050 |
- | - | - | - | $20,410 | 4,466 | - | - | - | - |
- - kWh |
- - kW-months/year |
$20,410 4,466 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1243 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER |
Savings: $9,950 Cost: $25,000 |
- | - | - | - | $9,950 | 2,177 | - | - | - | - |
- - kWh |
- - kW-months/year |
$9,950 2,177 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $34,146 Cost: $10,000 |
$1,873 | 49,030 | $643 | 67 | $31,630 | 6,921 | - | - | - | - |
$1,873 49,030 kWh |
$643 67 kW-months/year |
$31,630 6,921 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $7,231 Cost: $2,000 |
- | - | - | - | $7,231 | 1,582 | - | - | - | - |
- - kWh |
- - kW-months/year |
$7,231 1,582 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,038 Cost: $320 |
$326 | 8,540 | $113 | 12 | - | - | - | - | $599 | - |
$326 8,540 kWh |
$113 12 kW-months/year |
- - MMBtu |
- - $ |
$599 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $1,339 Cost: $1,600 |
$1,339 | 35,040 | - | - | - | - | - | - | - | - |
$1,339 35,040 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $494 Cost: $347 |
$494 | 12,930 | - | - | - | - | - | - | - | - |
$494 12,930 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,545 Cost: $8,000 |
$2,677 | 70,080 | - | - | - | - | - | - | $(-132) | - |
$2,677 70,080 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$(-132) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $10,085 Cost: $1,000 |
$9,145 | 239,400 | $3,140 | 328 | - | - | $(-1,000) | - | $(-1,200) | - |
$9,145 239,400 kWh |
$3,140 328 kW-months/year |
- - MMBtu |
$(-1,000) - $ |
$(-1,200) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $4,366 Cost: $1,800 |
$2,996 | 78,420 | $1,370 | 143 | - | - | - | - | - | - |
$2,996 78,420 kWh |
$1,370 143 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $2,264 Cost: $4,256 |
$1,685 | 44,123 | $579 | 60 | - | - | - | - | - | - |
$1,685 44,123 kWh |
$579 60 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $241,580 Cost: $156,373 |
$168,283 | 1,531,341 | $18,874 | 1,971 | $52,656 | 11,521 | $(-1,000) | - | $2,767 | - | $168,283 1,531,341 kWh |
$18,874 1,971 kW-months/year |
$52,656 11,521 MMBtu |
$(-1,000) - $ |
$2,767 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $180,337 Cost: $46,523 |
$125,023 | 398,865 | $4,604 | 480 | $48,811 | 10,680 | $(-1,000) | - | $2,899 | - | $125,023 398,865 kWh |
$4,604 480 kW-months/year |
$48,811 10,680 MMBtu |
$(-1,000) - $ |
$2,899 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |