Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
94
matching recommendationsNAICS | 32541 | Pharmaceutical and Medicine Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0224 # 02 Y:2003 | 02 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $351,990 | $119,086 | n/a |
MS0224 # 10 Y:2003 | 10 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,641 | $181 | Implemented |
MS0224 # 09 Y:2003 | 09 | 2003 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $8,477 | $1,560 | Not Implemented |
MS0224 # 12 Y:2003 | 12 | 2003 | INSULATE BARE EQUIPMENT | $3,422 | $301 | Not Implemented |
MS0224 # 03 Y:2003 | 03 | 2003 | INSTALL STEAM TRAP | $76,374 | $12,262 | Not Implemented |
MS0224 # 04 Y:2003 | 04 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $68,515 | $153,750 | Not Implemented |
MS0224 # 01 Y:2003 | 01 | 2003 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $936,645 | $8,400,000 | n/a |
MS0224 # 07 Y:2003 | 07 | 2003 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $26,018 | $50,000 | n/a |
MS0224 # 08 Y:2003 | 08 | 2003 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $12,652 | $0 | Not Implemented |
MS0224 # 06 Y:2003 | 06 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $31,243 | $26,302 | Implemented |
MS0224 # 05 Y:2003 | 05 | 2003 | MAINTAIN STEAM JETS USED FOR VACUUM SYSTEM | $37,053 | $70,000 | n/a |
MS0224 # 11 Y:2003 | 11 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,861 | $7,596 | Implemented |
MI0058 # 03 Y:2003 | 03 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,543 | $223 | Not Implemented |
MI0058 # 01 Y:2003 | 01 | 2003 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $11,548 | $2,000 | Not Implemented |
MI0058 # 06 Y:2003 | 06 | 2003 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $13,520 | $400,000 | Implemented |
MI0058 # 05 Y:2003 | 05 | 2003 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $250,000 | $43,000 | Implemented |
MI0058 # 04 Y:2003 | 04 | 2003 | METER WASTE WATER | $12,786 | $1,950 | Not Implemented |
MI0058 # 02 Y:2003 | 02 | 2003 | REPAIR OR REPLACE STEAM TRAPS | $1,906 | $696 | Implemented |
MI0057 # 01 Y:2003 | 01 | 2003 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $17,331 | $1,000 | Not Implemented |
MI0057 # 02 Y:2003 | 02 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $10,356 | $3,900 | Not Implemented |
MI0057 # 05 Y:2003 | 05 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,707 | $6,341 | Not Implemented |
MI0057 # 04 Y:2003 | 04 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,284 | $441 | Not Implemented |
MI0057 # 07 Y:2003 | 07 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $38,829 | $70,000 | Not Implemented |
MI0057 # 06 Y:2003 | 06 | 2003 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $7,443 | $400,000 | Implemented |
MI0057 # 09 Y:2003 | 09 | 2003 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $250,000 | $43,000 | Not Implemented |