Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

148

matching recommendations
Reset
NAICS 325411 Medicinal and Botanical Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0391 # 01 Y:2009 01 2009 INCREASE AMOUNT OF CONDENSATE RETURNED $5,716 $10,000 Implemented
NC0391 # 02 Y:2009 02 2009 FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM $18,020 $25,000 Implemented
NC0391 # 03 Y:2009 03 2009 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $5,889 $6,500 Not Implemented
NC0391 # 04 Y:2009 04 2009 DEVELOP A REPAIR/REPLACE POLICY $4,320 $6,886 Not Implemented
NC0391 # 05 Y:2009 05 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $257 $100 Implemented
NC0391 # 06 Y:2009 06 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,946 $59,958 Not Implemented
DL0031 # 01 Y:2008 01 2008 TURN OFF EQUIPMENT WHEN NOT IN USE $3,200 $0 Not Implemented
DL0031 # 02 Y:2008 02 2008 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $693 $0 Implemented
DL0031 # 03 Y:2008 03 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,826 $0 Not Implemented
DL0031 # 04 Y:2008 04 2008 INSTALL OCCUPANCY SENSORS $2,224 $0 Not Implemented
DL0031 # 05 Y:2008 05 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,809 $229 Implemented
DL0031 # 06 Y:2008 06 2008 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $7,857 $5,600 Not Implemented
DL0031 # 07 Y:2008 07 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $7,430 $0 Not Implemented
DL0031 # 08 Y:2008 08 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,757 $0 Not Implemented
DL0031 # 09 Y:2008 09 2008 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $3,944 $7,500 Implemented
DL0028 # 01 Y:2008 01 2008 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $122,000 $160,000 Not Implemented
DL0028 # 02 Y:2008 02 2008 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $47,800 $15,000 Implemented
DL0028 # 03 Y:2008 03 2008 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $10,400 $5,000 Not Implemented
DL0028 # 04 Y:2008 04 2008 INSTALL / REPAIR INSULATION ON STEAM LINES $13,700 $3,000 Implemented
DL0028 # 05 Y:2008 05 2008 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,900 $2,520 Implemented
DL0028 # 06 Y:2008 06 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,080 $500 Not Implemented
DL0028 # 07 Y:2008 07 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $9,100 $12,000 Not Implemented
DL0028 # 08 Y:2008 08 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,290 $12,000 Implemented
DL0028 # 09 Y:2008 09 2008 ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF $1,400 $400 Implemented
DL0028 # 10 Y:2008 10 2008 USE SOLAR HEAT TO MAKE ELECTRICTY $134,000 $1,275,000 Not Implemented